99
Chapter 3: Maintenance analysis procedures
513
Optical transceiver hot-removal completed.
No action required.
514
Optical transceiver failure.
Go to
MAP 0500
515
Optical digital diagnostics warning threshold exceeded.
Go to
MAP 0500
.
516
Optical digital diagnostics alarm threshold exceeded.
Go to
MAP 0500
.
523
FL_Port open request failed.
No action required.
524
No AL_PA acquired.
No action required.
525
FL_Port arbitration timeout.
No action required.
581
Implicit incident.
Go to
MAP 0500
.
582
Bit error threshold exceeded.
Go to
MAP 0500
.
583
Loss of signal or loss of synchronization.
Go to
MAP 0500
.
584
Not operational primitive sequence received.
Go to
MAP 0500
.
585
Primitive sequence timeout.
Go to
MAP 0500
.
586
Invalid primitive sequence received for current link state.
Go to
MAP 0500
.
810
High temperature warning (CTP thermal sensor).
Go to
MAP 0400
.
811
Critically hot temperature warning (CTP thermal sensor).
Go to
MAP 0400
.
812
CTP card shutdown due to thermal violations.
Go to
MAP 0400
.
850
Switch shutdown due to CTP thermal violations.
Go to
MAP 0400
.
Table 7
Event codes versus maintenance action (Continued)
Event
code
Explanation
Action
Содержание SAN32M-2
Страница 2: ......
Страница 10: ...SAN32M 2 Installation and Service Manual xii...
Страница 14: ...SAN32M 2 Installation and Service Manual xvi...
Страница 42: ...SAN32M 2 Installation and Service Manual 16...
Страница 120: ...SAN32M 2 Installation and Service Manual 94...
Страница 174: ...SAN32M 2 Installation and Service Manual 148...
Страница 236: ...SAN32M 2 Installation and Service Manual 210...
Страница 240: ...SAN32M 2 Installation and Service Manual 214...
Страница 244: ...SAN32M 2 Installation and Service Manual 218...
Страница 290: ...SAN32M 2 Installation and Service Manual 264...
Страница 308: ...SAN32M 2 Installation and Service Manual 282...
Страница 311: ......
Страница 312: ...Printed in USA GC26 7763 01...