187
Chapter 4: Repair information
Figure 60
Swap Ports dialog box
4. Notify the customer that a port swap is to be performed. Ensure
the customer’s system administrator quiesces Fibre Channel
frame traffic through the ports, varies any attached host offline,
and sets any attached device offline.
5. Click
Next
. Beaconing is enabled for both ports and both ports are
blocked. Swap the port fiber-optic cables as directed by the
customer’s system administrator.
6. Click
Next
. The
Instructions
section of the dialog box indicates the
port swap operation is complete and beaconing is disabled. Select
each
Unblock
check box to unblock the ports, then click
Finish
.
7. Ensure the customer’s system administrator varies any attached
host online and sets any attached device online.
8. Back up the product configuration data. Refer to
Back up
configuration
for instructions.
Collect maintenance data
When firmware detects a critical error, the product automatically
copies the contents of DRAM to a dump area in FLASH memory on
the CTP card. Perform this procedure after a firmware fault or
FRU/CRU failure to capture data for analysis by support personnel.
Maintenance data includes the dump file and engineering logs.
i1
6M2
01
9
Содержание SAN32M-2
Страница 2: ......
Страница 10: ...SAN32M 2 Installation and Service Manual xii...
Страница 14: ...SAN32M 2 Installation and Service Manual xvi...
Страница 42: ...SAN32M 2 Installation and Service Manual 16...
Страница 120: ...SAN32M 2 Installation and Service Manual 94...
Страница 174: ...SAN32M 2 Installation and Service Manual 148...
Страница 236: ...SAN32M 2 Installation and Service Manual 210...
Страница 240: ...SAN32M 2 Installation and Service Manual 214...
Страница 244: ...SAN32M 2 Installation and Service Manual 218...
Страница 290: ...SAN32M 2 Installation and Service Manual 264...
Страница 308: ...SAN32M 2 Installation and Service Manual 282...
Страница 311: ......
Страница 312: ...Printed in USA GC26 7763 01...