| Troubleshooting Equipment Problems |
265
1.
Check the battery contacts and the charger contacts for dirt or other obstructions that might prevent the contacts
from connecting properly.
2.
Clean the contacts, if necessary.
a) Use an isopropyl alcohol (isopropanol) swab or soft cloth dampened with isopropyl alcohol to clean metal
connection points.
b) If dirt or residue cannot be removed with the alcohol swab or cloth, use a soft, non-abrasive rubber eraser to
clean metal connection points. You can also use a three-row toothbrush style, general cleaning brush with
natural hog hair bristles to gently brush away dirt on the contacts.
c) Wipe again with isopropyl alcohol.
3.
Try various combinations of batteries and chargers to determine if the condition is specific to the battery or to the
charger.
• If the condition is specific to the battery, give the battery to your system administrator.
• If the condition is specific to the charger, disconnect the charger from its power source for about five seconds,
then reconnect it. Test the charger with a battery. If the same condition occurs, return the charger for service.
About Error Messages
Error messages may be of one of two types:
Numbered Messages display in VoiceConsole as the numeric value of the error, followed by the text message that
displays in Debug. If you have seen a numbered error message in VoiceConsole, see the Numbered Error Messages
topic.
Spoken Messages are heard through a headset. If you have heard an error message through a headset, see the Spoken
Error Messages topic.
Note:
Not all numbered error messages displayed in VoiceConsole have a corresponding spoken message.
Numbered Error Messages
Number
Text
Solution
0x020a
Event detect initialization
failed.
0x0203
Event control failed to create
shared data module.
1.
Turn the device off and then turn it back on
again.
2.
Reboot the device.
3.
Reload VoiceClient.
0x0206
Battery is getting low.
0x0207
Battery is getting low. Change
battery now.
0x0208
Battery is very low. Powering
off. Must replace battery after
power off complete.
Change the battery.
0x0602
Noise sampling procedure
failed.
—
0x0603
Noise sampling procedure
timed out.
—
0x0605
Invalid operator file name.
—
Содержание Vocollect
Страница 1: ...Honeywell Vocollect Hardware Reference ...
Страница 2: ......
Страница 4: ......
Страница 12: ......
Страница 20: ......
Страница 36: ......
Страница 80: ......
Страница 106: ......
Страница 128: ......
Страница 148: ......
Страница 150: ......
Страница 154: ... Honeywell Wired Headsets 154 ...
Страница 166: ......
Страница 287: ... Honeywell Regulatory Compliance 287 Japanese Compliance Brazilian Compliance ...
Страница 308: ......
Страница 316: ... Index 316 ...