Operation - Logs
Part No.: 4418309_Rev09
Fusion4 MSC-L
Honeywell
Installation & Operation Manual
5 - 213
5.15.8.5 Clean Arm Underrun
5.15.8.6 Stop Switch not covered
5.15.8.7 Fixed
5.16 Logs
To perform the Logs functions
On the
Main Menu
screen, select the
<Logs>
icon.
Entity
Description
Value range
[Alarm Action]
With this entity you can configure the
alarm behavior, in case this alarm
occurs.
<Disabled>
<Display>
<Display shutdown>
(default)
<Display pause>
[Clean arm underrun]
The measured clean arm volume is
less than the specified clean arm
volume minus the clean arm tolerance.
default
= <5.00>
L
Entity
Description
Value range
[Alarm action]
With this entity you can configure the
alarm behavior, in case this alarm
occurs.
<Disabled>
<Display>
<Display shutdown>
<Display pause>
(default)
[Stop switch timeout]
With this entity you can configure the
time within which a feedback should be
received from the Stop/Low/High flow
rate switches
<0-65535s>
<10s>
(default)
[Stop switch auto clear timeout]
With this entity you can reset the Stop
switch not covered alarm and continue
unloading the truck until its empty.
<0-65535s>
<10s>
(default)
Entity
Description
Value range
[Arm parked alarm action]
With this entity you can configure the
alarm behavior, in case this alarm
occurs.
<Disabled>
<Display>
<Display shutdown>
<Display pause>
(default)
[Invalid switch states]
With this entity you can configure the
alarm behavior, in case switch states of
Stop flow switch, Low flow switch and
High flow switch are invalid.
<Disabled>
<Display>
<Display shutdown>
<Display pause>
(default)