Operation - Arm Configuration
Fusion4 MSC-L
Part No.: 4418309_Rev09
5 - 198
Installation & Operation Manual
Honeywell
With the
[High flow rate]
entity a second full flow rate can be configured.
This flow rate is used during the “Full flow” loading phase. This entity
relates to the
[High flow switch]
in the I/O binding.
When the input is active, the
[High flow rate]
is used during the “Full flow”
loading phase.
When the input is not active the
[Full flow rate]
is used during the “Full
flow” loading phase.
When no I/O binding is configured always the
[Full flow rate]
will be used
during the “Full flow” loading phase.
For a correct configuration the
[Full flow rate]
must be set to a higher value
than the
[High flow rate]
.
In case also the
[Stop flow switch]
and the
[Low flow switch]
I/O binding are
configured those three switched will be used for unloading operation
controlling the air eliminator.
5.15.4 Arm Configuration . Arm n . Product Streams
1. On the
Arm Configuration . Arm n
screen, select
<Product stream
selection>
.
[Batch full flow resume time]
With this entity you can configure the
batch full flow resume time. When
which is paused in full flow state is
resumed, full flow rate alarm condition
check is disabled for this duration to
allow for time needed to achieve full
flow.
<0>
s to
<99>
s
default:
<0>
s
[Batch lineup time]
With this entity you can set the Inter
mini batch lineup time (delay) which is
used for sequential blending. When set
to 0, batch will be paused between mini
batches and has to be resumed
manually
<0>
s to
<99>
s
default:
<1>
s
Entity
Description
Value range