Installation - Wiring Termination Guidance
Fusion4 MSC-L
Part No.: 4418309_Rev09
4 - 82
Installation & Operation Manual
Honeywell
CN-244
1
PO-3
HI
Po3_HI
Feed
Pulse output
control
2
PO-3
LO
Po3_LO
Signal - Output
3
PO-4
HI
Po4_HI
Feed
4
PO-4
LO
Po4_LO
Signal - Output
CN-245
1
AO-5
+
AO_a5
Signal - Output
(+)
Analog output
control
2
AO-5
-
AO_b5
Signal - Output
(-)
3
AO-6
+
AO_a6
Signal - Output
(+)
4
AO-6
-
AO_b6
Signal - Output
(-)
5
AO-4
+
AO_a4
Signal - Output
(+)
6
AO-4
-
AO_b4
Signal - Output
(-)
CN-246
1
COM-6
+
RS485_A_CH6
Receive
RS485
communication
interface (2-wire)
Preferred interface
to:
TAS
Fusion4 Portal
Smart Additive
2
COM-6
-
RS485_B_CH6
Transmit
3
COM-6
C
RS485_Commo
n_CH6
0 V
4
COM-7
+
RS485_A_CH7
Receive
5
COM-7
-
RS485_A_CH7
Transmit
6
COM-7
C
RS485_Commo
n_CH7
0 V
Terminal
I/O
Floor plan
ID
Signal name
Signal
description
Type
Typical
functions