System Description - Available Input/Output Functions of the MSC-L
Fusion4 MSC-L
Part No.: 4418309_Rev09
3- 38
Installation & Operation Manual
Honeywell
• German
• Dutch
• Spanish
• Chinese
• Japanese
• Polish
• Portuguese
• Italian
• Thai
• One additional configurable user language
Menu driven service interface:
• LAD intrinsic safe interface.
• IR interface, which is compatible with the Fusion4 IR Controller.
• Real-time clock for time stamping.
• Seven communication ports and three ethernet ports for inter
-
facing with the safe area tools and systems.
3.6.5 Environment
1 Restriction of Hazardous Substances.
3.7 Available Input/Output Functions of the MSC-L
The following table lists the different types of interfaces supported by
the boards.
Parameter
MSC
LAD
Operating temperature
-40 °C ... +65 °C (-40 ºF ... +149 ºF)
-20 °C ... +65 °C (-4 ºF ... +149 ºF)
Electronics designed
-40 °C ... +85 °C (-40 ºF ... +185 ºF)
and
RoHS
1
-40 °C ... +85 °C (-40 ºF ... +185 ºF)
and
RoHS
1
Storage temperature
-40 °C ... +85 °C (-40 ºF ... +185 ºF)
-40 °C ... +85 °C (-40 ºF ... +185 ºF)
Ingress protection
IP66 / NEMA 4X
IP54 / NEMA 3R
SD-card compartment behind lid
-
IP20
I/O block
CAN-ARM-MSC CAN-IN-OUT-MSC CAN-HMI-MSC
Refer to
section
Single Pulse Input / DI DC Input
12
15
0
3.8.2 and
Dual Pulse Input (Quad PI)
6
0
0
Analog Input (4-20mA Active/Passive)
7
0
0
Resistance Temperature Detector
-
RTD Temperature Input (3-wire or 4-
wire)
3
0
0