79
[Initial value] 1000[ms]
[Setting range] 0 to 60000[ms]
387. 0
[Basic setting]
JOG operation:
Target speed
Set a target speed of the JOG operation.
[Initial value] 300[ r/mi n]
[Setting range] For 50W
~
100W
:
0
~
6300[ r/mi n]
For 200W
~
400W
:
0
~
5000[ r/mi n]
For 750W: 4500[ r/mi n]
For 1kW
~
2kW
:
0
~
3000[ r/mi n]
Note) Alarm occurs when it exceeds max. speed. Do not exceed the max.speed.
No
388.0
[Basic setting]
Selection of
Internal speed
command type
It is valid when control mode No.2.0 is set to “1=speed control mode”
and command
mode selection No.3.0 is set to “3=Internal generation command” . Select command
type of internal speed command. No.390.0 and No.391.0 are used to set
acceleration/deceleration time of internal speed command. No.392.0
~
399.0 are used
to set the target speed.
0 = zero command input
1 = internal speed command(trapezoid speed command with 8 phases)
[Initial value] 0
[Setting range] 0 or 1
No
390.0
[Basic setting]
Internal speed
command
Acceleration time
It is valid when control mode No.2.0 is set to “1=speed control mode” , command
mode selection No.3.0 is set to “3=Internally generated command” , and internal
speed command type No.388.0 is set to “1= trapezoidal speed command” . Set the
acceleration time of internal speed command input. Set the time of speed command
from 0rpm to 1000rpm. No.391.0 is used to set internal speed command deceleration
time. No.392.0
~
399.0 are used to set the target speed.
[Initial value] 1000 [ms]
[Setting range] 0 to 60000
No
391.0
[Basic setting]
Internal speed
command
Deceleration time
It is valid when control mode No.2.0 is set to “1=speed control mode” , command
mode selection No.3.0 is set to “3=Internal generation command”
, and internal
speed command type No.388.0 is set to “1= trapezoidal speed command” . Set the
deceleration time of internal speed command input. Set the time of speed command
from 1000rpm to 0rpm. No.390.0 is used to set internal speed command acceleration
time. No.392.0
~
399.0 are used to set the target speed.
[Initial value] 1000 [ms]
[Setting range] 0 to 60000
No
392.0
393.0
394.0
395.0
396.0
397.0
398.0
399.0
[Basic setting]
Internal
speed
command
Target speed 1
Target speed 2
Target speed 3
Target speed 4
Target speed 5
Target speed 6
Target speed 7
It is valid when control mode No.2.0 is set to “1=speed control mode” , command
mode selection No.3.0 is set to “3=Internal generation command”
, and internal
speed command type No.388.0 is set to “1= trapezoidal speed command” . Internal
speed command acceleration/deceleration time is set in No.390.0 and No.391.0. Set
8-phase target speed of internal speed command input. The switch of target speed can
be realized by following combination of 8pin, 9pin and 10pin in CN1.
Target speed
I5(8pin in CN1)
I6(9pin in CN1)
I7 (10pin in CN1)
1
Open
Open
Open
2
Short circuited
Open
Open
3
Open
Short circuited
Open
No