152
Figure 8.9.26 Overview diagram with horizontal axis(home position return with Home position DOG front end)
Note) ) I/O state: “C” indicates the closed-circuit for internal output circuit contact or external contact.
“O” indicates open-circuit.
Figure 8.9.27 Timing chart ((home position return with Home position DOG front end)
・
When set the Action at home position return completion(No. 647. 1) to “No move”, it will not shift to the home position and
end the action.
・
When set Home position Base signal 1 redetection (No. 645. 3) to “Disable”, no backward action for detecting home position
DOG front end.
・
When start the home position return on the home position sensor, it will be back to home position DOG sensor front end and
have the home position DOG front end detection with home position return creep speed.
2) When use Encoder phase Z
Set “Base signal 2 selection for Home position” to “1=Encoder phase Z”.