Please note that there is high voltage in the solid line of wiring diagram when wiring and using.
②
The broken lines in the wiring diagram indicates the non-dangerous voltage circuit.
4.1.2 Connection of servo drive and motor
Items
Description
Peripheral device
Conform to European EC Directive. Select the device which meets corresponding standards
and install them in accordance with User’s Manual.
Installation environment
Install the servo drive to the environment which conform to Pollution degree 2 or 1 of
IEC60664-1.
Power supply 1: 200
~
230VAC (main circuit)
This product can be used under the conditions that conform to IEC60664-1 and overvoltage
category
Ⅱ
.
Power supply 2: 24VDC
♦control power supply of drive
♦I/O power supply
♦Power supply for brake
release
The specification of 24VDC external power supply should satisfy the following conditions.
Using SELV power supply(
※
) and power less than 150W. This is the CE corresponding
conditions.
※
SELV: safety extra low voltage
(Reinforced insulation is needed for safety extra low voltage, non-dangerous voltage and
dangerous voltage.)
Wiring
Please use withstand voltage cables which are equivalent to AWG18/600V or AWG14/600V
for motor power cable, encoder cable, AC220 input cable, FG cable and main circuit power
distribution cable under multi-axis drive structure respectively when drives are less than
750W or more than 1kW .
Breaker
Switch off the power supply to protect power cord when overcurrent occurs.
Make sure to use the breaker between power supply and interference filter that conforms to
IEC specification and UL recognition in accordance with the User manual.
Please use the breaker with leakage function recommended by HCFA in order to meet EMC
standards.
Noise filter
To prevent the outside interference from power cables.
Please use the interference filter recommended by HCFA in order to meet EMC standards.
Magnetic contactor
Switch main power supply (ON/OFF). And use it after installing a surge absorber.
Surge absorber
Please use the surge absorber recommended by HCFA in order to meet EMC standards.
Interference filter for signal
cable / ferrite filter
Please use the interference filter recommended by HCFA in order to meet EMC standards.
Regenerative resistor
This product is not equipped with regenerative resistor.
The external regenerative resistor is necessary when the internal capacitor cannot absorb
more regenerative power. Confirm the regenerative status on the panel. When the
regenerative voltage alarm is ON, a regenerative resistor is needed.
For the reference specification of regenerative resistor, please refer to user manual.
Use a built-in thermostat and set overheat protect circuit.
Grounding
This product belongs to Class 1 and need grounding protection.
Using protection grounding terminal. Grounding should be executed by the case and cabinet
that conforms to EMC.
The following symbol indicates the protection grounding terminal.