139
completed.
When selecting “Move”, after detecting the base signal for home position, deceleration to stop and perform the positioning
operation according to the parameter set.
No.
Name
Unit
648.0
Home position return Speed
rpm
Set Home position return Speed.
[Setting range] 1 to max. speed of the motor
[Initial value] 500
Figure 8.9.9 Home position return Speed
No.
Name
Unit
649.0
Home position return Creep speed
rpm
Set Creep speed after Home position Base signal 1 detection.
[Setting range] 1 to max. speed of the motor
[Initial value] 10
No.
Name
Unit
650.0
Home position return Acceleration/deceleration time
ms/1000rpm
Set Acceleration/Deceleration time for Home position return.
Set the acceleration time from speed 0 to 1000rpm and deceleration time from 1000 to 0rpm.
[Setting range] 0
~
5, 000
[Initial value] 30
No.
Name
Unit
651.0
Home position Return Shift-to-home-position quantity
Command unit(Note 1)
Set shift quantity from the position where the Base signal was detected to the home position.
In the situation except “1: Stopper” in home position base signal 1(No. 645. 0), the base signal begins to shift to the home
position(No. 646. 0). The home position returns according to the shift quantity(No. 646. 0).
If “1: Stopper” in home position base signal 1 is set, the direction between shift-to-home-position and home position return(No.
646. 0) is opposite.
[Setting range] 0
~
1, 000, 000, 000
[Initial value] 0[command unit]