65
upper controller.
[Initial setting] (Numerator / Denominator )=1000/1000
[Setting range] 0
~
65535/1
~
65535
052.0 /
053.0
[Basic setting]
Analog speed
command CCW
speed limit
threshold value
(Numerator /
Denominator )
Analog speed command CCW speed limit threshold value.
Analog command CCW speed limit = (the highest speed of motor) * (threshold
value(numerator))/ (threshold value(denominator))
[initial setting] (Numerator / Denominator )=5000/5000
[Setting range] 0
~
65535/1
~
65535
No
054.0 /
055.0
[Adjustment]
Analog speed
command CW
speed limit
threshold value
(Numerator /
Denominator )
Analog speed command CW speed limit threshold value.
Analog command CW speed limits = (the highest speed of motor) * (threshold
value(numerator))/ (threshold value(denominator))
[initial setting] (Numerator / Denominator )=5000/5000
[Setting range] 0
~
65535/1
~
65535
No
060.0
[Basic setting]
Analog
speed
command
fixed offset value
When using manual adjustment to adjust offset value of analog speed command, set
the adjustment value. It’s valid when the offset adjustment is selected to “1= manual
adjustment”. Adjust the corresponding analog speed command input to 0r/min at the
0V input voltage.
<setting method>.
1. Servo ON (motor will rotate if offset exists)
2. When rotating at the speed of
±
10r/min or less, set the value to
±
50 to confirm
the operation.
(CCW direction, set to
「
-50
」
; CW direction, set to
「
+50
」
.
3. Set the offset value while observing the motor operation. (If rotate at CCW direction,
setting values change in response to
「
-direction
」
. If rotate at CW direction, setting
values change in response to
「
+direction
」
.
[Initial value] 0
[Setting range] -32768/32768
No
062.0
[Basic setting]
Analog
speed
command rotation
direction
Select rotation direction of analog speed command.
0=Inputting negative voltage, the motor has CCW rotation; Inputting positive voltage,
the motor has CW rotation.
1= Inputting positive voltage, the motor has CCW rotation; Inputting negative voltage,
the motor has CW rotation.
[Initial value] 1 (Inputting positive voltage, the motor has CCW rotation)
[Setting range] 0 or 1
No
062.1
[Basic setting]
Select analog
speed command
input filter
Select analog speed command input filter.
Input filter constant can be set in No.048.0, No.049.0.
0= Disable
1=Enable (one IIR filter)
[Initial value] 1 (Enable)
[Setting range] 0 or 1
No
Содержание SV-E3 Series
Страница 21: ...21 ...
Страница 25: ...25 ...
Страница 27: ...27 ...
Страница 28: ...28 ...
Страница 29: ...29 ...
Страница 30: ...30 3 5 Dimensions of servo drive Same dimensions for SV E3 ...
Страница 41: ...41 Figure 5 3 1 ...