[Regenerative status]
Display main circuit DC power supply of drive and the working status of regenerative power circuit.
When
displays in the set panel, press SET button to show the following
Figure 5.4.4
Table 5.4.4 Display list of regenerative status
Display
Name
Description
ot00
Regenerative control output Indicates the drive working status of regenerative power circuit. When the signal is
ON, regenerative power is under the operation by regenerative resistor.
ot01
Reserved
『
-
』
fixed
:
:
:
ot07
Reserved
『
-
』
fixed
in00
Regenerative voltage alarm
When the DC voltage of main circuit reaches the regenerative voltage alarm, the
signal is ON, which indicates the drive regeneration circuit may be on working state. A
regenerative resistor is recommended to be connected.
When voltage is less than regenerative threshold voltage, the signal is ON.
in01
Regenerative
threshold
voltage
When the DC voltage of main circuit reaches regenerative threshold voltage, the
signal is ON, which indicates the drive regeneration circuit is on working state. A
regenerative resistor must be connected. If not, the power failure may occur.
in02
Reserved
『
-
』
fixed
:
:
:
Содержание SV-E3 Series