158
-Grounding or not
-Power cable wiring
・
Consult HCFA distributor if have not been
improved
26
Inverter error 2
・
Control circuit error
・
Servo ON timeout
27
Current
sensor
error
・
Ambient temperature of current sensor is too
high
・
Current sensor error
・
Check the setting and temperature of the drive
・
Consult HCFA distributor if have not been improved
Reset
29
Power
error
(Inside the drive)
・
Control power supply (DC5V) voltage drops
in the drive
・
Check if short-circuit on the encoder cable wiring
・
Consult HCFA distributor if have not been
improved
Reset
9.3 Troubleshooting
When no alarm occurs, confirm the following items if the drive does not operate and the motor does not rotate.
Figure 9.3.1
Status
Description
Reference items
Troubleshooting 1
No display on setting
panel
Switch on the control power supply (24V DC), but on any display
「
」
on the setting panel.
Table 9.3.1
Troubleshooting 2
Servo not ON
Even though
「
」
is displayed on the setting panel, the
servo cannot start.
Table 9.3.2
Troubleshooting 3
Motor cannot rotate
The servo is ON, but the motor will not operate.
Table 9.3.3
Troubleshooting 4
Motor operation not
steady
The motor operates unsteadily.
Table 9.3.4
Troubleshooting 5
Vibration and sound
Vibration and sound occurs when the motor operates.
Table 9.3.5
■
Troubleshooting 1 (No display on setting panel)
Switch on the control power supply (24V DC), but on any display of
「
」
on the setting panel.
Содержание SV-E3 Series
Страница 21: ...21 ...
Страница 25: ...25 ...
Страница 27: ...27 ...
Страница 28: ...28 ...
Страница 29: ...29 ...
Страница 30: ...30 3 5 Dimensions of servo drive Same dimensions for SV E3 ...
Страница 41: ...41 Figure 5 3 1 ...