![Hitachi IJ RX2 Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/hitachi/ij-rx2/ij-rx2_service-manual_143791043.webp)
2-26
2.9 Backup
●
Print data and user data are backed up on a USB memory.
●
Backup data can be copied on an IJ printer.
●
You can select the type of data when copying to the IJ printer.
●
The copying method is replacing the content of USB memory as they are (overwrite copy).
Types of copy target data
Types of data
Contents
Print data
▪
Includes the settings of print contents, print format and print
specifications.
▪
Registered print data is the target of backup; print target data is
not applicable for backup.
▪
To back up print target data, register them and back up as
registered print data.
Standard
character
Includes standard character patterns in all character sizes.
User pattern
Includes registered characters in all character sizes.
Unit-specific
data
(maintenance
screen setting
values, etc.)
User environment setup, date/time setup, communication
environment setup, circulation environment settings, system
environment setup, auto phase gain value, fault warning history,
touch panel coordinate information, display environment setup,
excitation setting value, viscosity information, login information,
Operating time, Ink alarm time, cumulative operating time, print
count, various usage time, logging data (viscosity data, ink
automatic replenishment data, circulation control data, fault
warning history, entry trace data)
Difference between copy target data maintenance modes
User maintenance mode
Service personnel
maintenance mode
Types of data
Backup
(IJP
USB memory)
Data copy
(USB memory
IJP
)
Backup
(IJP
USB memory)
Data copy
(USB memory
IJP
)
Print data
O
O
O
O
Standard
character
O
O
O
O
User pattern
O
O
O
O
Unit-specific data
O (*1)
X
O (*2)
O (*3)
(*1) Logging data output to binary file only.
(*2) Logging data output to either binary file or text file.
(Refer the chapter 2.19 for Detail of Logging text)
(*3) Can copy when the copy target folder has the same serial number as itself.
Data of multiple IJ printers can be backed up in a single USB memory.
A folder with the product serial number is created in the USB memory.
When copying backup data from the USB memory to the IJ printer, select the folder of the
data is to be copied.
A single USB memory can hold data for up to 100 IJ printers data. However cannot exceed
the capacity of the USB memory.
Use the auxiliary function menu for inserting/removing the USB memory.
Do not frequently insert/remove the USB memory.
When copying standard character pattern, execute the data copy function with the printer in
“Stop” state.
[Note]
Do not use the backup data made by RX model software version before V8.06 to the RX2 model
with SOP-15-19.
Содержание IJ RX2
Страница 1: ...Service Manual HITACHI Printer Model RX2 Revision Feb 2014 Version A ...
Страница 13: ...1 8 2 External views Rear side 1 2 2 Main body internal ...
Страница 14: ...1 9 1 2 3 Print head ...
Страница 101: ...3 26 Circuit diagram of EZJ127A ...
Страница 102: ...3 27 Circuit diagram of EZJ127B ...
Страница 116: ...3 41 Circuit diagram of EZJ129 ...
Страница 164: ...4 40 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 247: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram 7 1 ...
Страница 248: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram RX2 S Standard model 7 2 ...
Страница 249: ...7 3 7 2 2 Electrical Connection Diagram RX2 B Basic model 7 3 ...
Страница 252: ... Nozzle diameter 65μm 7 6 7 4 Dimensions around charge electrode and deflection electrode 循環系統図 ...