6-8
6.2.6 System Operation error C / M / S
Does the fault
recur?
Do the system reset by rescue soft
Properly establish the
ground connection.
確実にア ース を 接続する
END
終了
No
Yes
Noise Fault M/S
ノ イ ズエラ ーM/S
Yes
Ensure that the print head
and printer main body are
not in contact with the
other equipment.
Does the fault
recur?
No
No
No
Yes
System Operation error C / M / S
Are the nozzle head
and IJ printer main
body insulated from
the other equipment?
Is the IJ printer
connected to its
dedicated ground?
▪ Clear the fault.
▪ Restart the IJ printer.
Replace the EZJ126 board.
Replace the multiple
power supply.
Does the fault
recur?
ノ イ ズエラ ーが
発生する か
Replace the EZJ128 board.
EZJ128
基板を 交換する
Noise Fault C
ノ イ ズエラ ーC
Yes
Used the SOP05 for
call up print data?
Yes
The strobe input timing is
following the regulation?
Input the strobe signal with
correct timing of the SOP05
instruction.
No
Yes
No
Yes
No
Содержание IJ RX2
Страница 1: ...Service Manual HITACHI Printer Model RX2 Revision Feb 2014 Version A ...
Страница 13: ...1 8 2 External views Rear side 1 2 2 Main body internal ...
Страница 14: ...1 9 1 2 3 Print head ...
Страница 101: ...3 26 Circuit diagram of EZJ127A ...
Страница 102: ...3 27 Circuit diagram of EZJ127B ...
Страница 116: ...3 41 Circuit diagram of EZJ129 ...
Страница 164: ...4 40 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 247: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram 7 1 ...
Страница 248: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram RX2 S Standard model 7 2 ...
Страница 249: ...7 3 7 2 2 Electrical Connection Diagram RX2 B Basic model 7 3 ...
Страница 252: ... Nozzle diameter 65μm 7 6 7 4 Dimensions around charge electrode and deflection electrode 循環系統図 ...