Getting Started
75/299
PC Cards cifX Compact PCI, Mini PCI, Mini PCIe, PCI-104 | Installation, Operation and Hardware Description
DOC120205UM53EN | Revision 53 | English | 2019-03 | Released | Public
© Hilscher, 2008-2019
System
Note
DeviceNet Slave
To configure the Master, an EDS file (device description file) is required. The settings in the
used Master must comply with the settings in the Slave to establish communication. Important
parameters are: MAC ID, Baudrate, Produced Size, Consumed Size, Vendor ID, Product Type,
Product Code, Major Rev, Minor Rev.
CC-Link Slave
To configure the Master, a CSP file (device description file) is required. The settings in the used
Master must comply with the settings in the Slave to establish communication. Important
parameters are: Slave Station Address, Baudrate, Station Type and Vendor Code.
Table 41: Notes for the Configuration of the Master Device
Further information to the device description files you find under section
on
page 25.
4.5 Device Names in SYCON.net
The following table contains the device names displayed for the single
communication protocols in the configuration software SYCON.net.
The table shows the PC card cifX and which protocol can be used. Further-
more, the table shows, for which protocol which device must be selected
from the device catalog to configure the PC card cifX with SYCON.net.
PC Cards cifX
Protocol
DTM Specific Group
Device Name in
SYCON.net
CC-Link IE Field Basic Slave
Gateway/Stand-Alone Slave CiFX
RE/CCIBS
EtherCAT Master
Master
CIFX RE/ECM
EtherCAT Slave
Gateway/Stand-Alone Slave
CIFX RE/ECS
EtherNet/IP Scanner (Master)
Master
CIFX RE/EIM
EtherNet/IP Adapter (Slave)
Gateway/Stand-Alone Slave
CIFX RE/EIS
Open Modbus/TCP
Gateway/Stand-Alone Slave
CIFX RE/OMB
POWERLINK-Controlled-Node/Slave Gateway/Stand-Alone Slave
CIFX RE/PLS
PROFINET IO-Controller
Master
CIFX RE/PNM
PROFINET IO-Device
Gateway/Stand-Alone Slave
CIFX RE/PNS
Sercos Master
Master
CIFX RE/S3M
Sercos Slave
Gateway/Stand-Alone Slave
CIFX RE/S3S
CIFX 80-RE,
CIFX 90-RE\F,
CIFX 90-RE\F\M12,
CIFX 90E-RE\F,
CIFX 90E-RE\F\M12,
CIFX 90E-RE\NHS\F,
CIFX 90E-RE\NHS\F\M12,
CIFX 90E-RE\ET\F,
CIFX 90E-RE\ET\F\M12,
CIFX 90E-RE\MR\F
CIFX 90E-RE\MR\F\M12,
CIFX 90E-RE\MR\ET\F,
CIFX 90E-RE\MR\ET\F\M12,
CIFX 104C-RE,
CIFX 104C-RE-R,
CIFX 104C-RE\F,
CIFX 104C-RE\F\M12,
CIFX 104C-RE-R\F,
CIFX 104C-RE-R\F\M12
VARAN Client (Slave)
Gateway/Stand-Alone Slave
CIFX RE/VRS
PROFIBUS DP Master
Master
CIFX DP/DPM
PROFIBUS DP Slave
Gateway/ Stand-Alone Slave
CIFX DP/DPS
CIFX 80-DP, CIFX 90-DP\F,
CIFX 90E-DP\F,
CIFX 90E-DP\NHS\F,
CIFX 90E-DP\ET\F,
CIFX 90E-DP\MR\F,
CIFX 90E-DP\MR\ET\F,
CIFX 90E-2DP\ET\F
CIFX 90E-2DP\MR\ET\F
CIFX 90E-2DP\CO\ET\F
CIFX 90E-2DP\CO\MR\ET\F
CIFX 90E-2DP\DN\ET\F
CIFX 90E-2DP\DN\MR\ET\F
CIFX 104C-DP,
CIFX 104C-DP-R,
CIFX 104C-DP\F,
CIFX 104C-DP-R\F
PROFIBUS MPI Device
Gateway/ Stand-Alone Slave
CIFX DP/MPI
CANopen Master
Master
CIFX CO/COM
CIFX 80-CO, CIFX 90-CO\F,
CIFX 90E-CO\F,
CIFX 90E-CO\NHS\F,
CIFX 90E-CO\ET\F,
CIFX 90E-CO\MR\F,
CIFX 90E-CO\MR\ET\F,
CIFX 90E-2CO\ET\F
CANopen Slave
Gateway/ Stand-Alone Slave
CIFX CO/COS