Technical Data
222/299
PC Cards cifX Compact PCI, Mini PCI, Mini PCIe, PCI-104 | Installation, Operation and Hardware Description
DOC120205UM53EN | Revision 53 | English | 2019-03 | Released | Public
© Hilscher, 2008-2019
CIFX 104C-DN,
CIFX 104C-DN-R
Parameter
Value
Width for the data access to the
Dual-Port Memory (DPM)
32-Bit
DeviceNet
Communication
Supported communication
standard/ protocol (determined by
the loaded firmware)
DeviceNet Master,
DeviceNet Slave
Transmission Rate
125 kBit/s, 250 kBit/s, 500 kBit/s
Interface Type
ISO-11898 according to DeviceNet specification,
refer to section
Galvanic Isolation
isolated (optically isolated)
Isolation Voltage
1000 VDC (tested for 1 minute)
DeviceNet Interface
Connector
CombiCon male Connector, 5-polig
Diagnosis Interface
USB Interface
Mini B USB Plug (5 pin), refer to section
, page 156.
SYS
System Status LED
MNS
Module network status (duo LED)
Display LED
Display
The meaning of the MNS LED is depending on loaded
firmware. Refer to chapter
, page 115..
Supply Voltage
+5 V dc ±5 % or +3.3 V dc ±5 %, refer to section
Current consumption
at 5 V …………………..
or
at 3.3 V…………………
500 mA (maximum)
650 mA (maximum)
Power supply
Connector
Via PCI-104 Bus
Rotary Switch
PCI-104 Slot Number
To set the PCI-104 Slot Number, refer to section
Switch for PCI-104 Slot Number
Operation
Rotary Switch Device Address
Is currently unassigned. Refer to section
Operating temperature range*
-20 °C ... +70 °C
(
acc. to UL: 0 °C ... +55 °C
)
*Air flow during measurment
0,5 m/s
Storage temperature range
-40 °C ... +85 °C
Humidity
10 … 95% relative humidity, no condensation permitted
Environmental
Conditions
Environment
For UL compliant usage:
The device must be used in a pollution degree 2
environment.
Dimensions (L x W x H)
97 x 91 x 24 mm
Mounting/Installation
PCI-104 Slot (Supply Voltage 5 V or 3.3 V, Signaling Vol-
tage 5 V or 3.3 V), refer to section
cifX Compact PCI, Mini PCI, Mini PCIe, PCI-104
Device
RoHS Yes
CE Sign
Yes
Emission
EN 55011:2009 + A1:2010, CISPR 11:2009, Class A
(Radio disturbance characteristics - Limits and methods of
measurement)
CE Sign
Immunity
EN 61000-4-2:2009 (Electrostatic discharge test)
EN 61000-4-3:2006 + A1:2008 + A2:2010 (Radiated,
radio-frequency, electromagnetic field test)
EN 61000-4-4:2004 + A1:2010 (Burst Electrical fast
transients/burst test)
EN 61000-4-5:2006 (Surge test)
EN 61000-4-6:2009 (to conducted disturbances, induced
by radio- frequency fields)