Technical Data
175/299
PC Cards cifX Compact PCI, Mini PCI, Mini PCIe, PCI-104 | Installation, Operation and Hardware Description
DOC120205UM53EN | Revision 53 | English | 2019-03 | Released | Public
© Hilscher, 2008-2019
CIFX 80-DP
Parameter
Value
Emission
EN 55011:2009 + A1:2010, CISPR 11:2009, Class A
(Radio disturbance characteristics - Limits and methods of
measurement)
Immunity
EN 61000-4-2:2009 (Electrostatic discharge test)
EN 61000-4-3:2006 + A1:2008 + A2:2010 (Radiated,
radio-frequency, electromagnetic field test)
EN 61000-4-4:2004 + A1:2010 (Burst Electrical fast
transients/burst test)
EN 61000-4-5:2006 (Surge test)
EN 61000-4-6:2009 (to conducted disturbances, induced
by radio- frequency fields)
EN 61000-4-8:2010 (power frequency magnetic field test)
EN 61000-6-2:2005 + B1:2011 (for industrial
environments)
UL Certification
The device CIFX 80-DP is
certified according to UL 508
UL-File-Nr. E221530
Configuration Software
Master and Slave
SYCON.net
Configuration
Configuration Software Slave
netX Configuration Tool
Table 132: Technical Data CIFX 80-DP
10.1.3 CIFX
80-CO
CIFX 80-CO
Parameter
Value
Name, Part No.
CIFX 80-CO
1280.500
Description
PC Card cifX Compact PCI CANopen Master or Slave
Part
Function
Communication interface with Compact PCI and CANopen
interface
Communication
Controller
Type netX
100
processor
RAM
8 MB SDRAM
FLASH
4 MB serial Flash EPROM
Integrated Memory
Size of the Dual-Port Memory
64 KByte
Bus Type
Compact PCI, according to [bus spec 4], refer to section
Transmission Rate
33 MHz
Data Access
DPM or DMA (Direct Memory Access)
System Interface
Width for the data access to the
Dual-Port Memory (DPM)
32-Bit
CANopen
Communication
Supported communication
standard/ protocol (determined by
the loaded firmware)
CANopen Master,
CANopen Slave
Transmission rate
10 kBit/s, 20 kBit/s, 50 kBit/s, 100 kBit/s, 125 kBit/s,
250 kBit/s, 500 kBit/s, 800 kBit/s, 1 MBit/s
Interface Type
ISO-11898, refer to section
Galvanic Isolation
optically isolated
Isolation Voltage
1000 VDC (tested for 1 minute)
CANopen Interface
Connector
DSub male Connector, 9 pin
Diagnostic Interface
USB Interface
Mini B USB Plug (5 pin), refer to section
, page 156.
SYS
System Status LED
Display LED
Display
CAN
CANopen Status (duo LED)