Technical Data
190/299
PC Cards cifX Compact PCI, Mini PCI, Mini PCIe, PCI-104 | Installation, Operation and Hardware Description
DOC120205UM53EN | Revision 53 | English | 2019-03 | Released | Public
© Hilscher, 2008-2019
CIFX 90E-DP\F
and Variants
Parameter
Value
Connector
Via Mini PCI Express Bus
CIFX 90E-DP\F,
CIFX 90E-
DP\NHS\F,
CIFX 90E-DP\MR\F
CIFX 90E-DP\NHS\F CIFX 90E-DP\ET\F,
CIFX 90E-
DP\MR\ET\F
Operating temperature range*
0 °C ... +55 °C
0 °C ... +45 °C
-20 °C ... +70 °C
*Air flow during measurment
0,5 m/s
0,0m/s
0,5 m/s
Storage temperature range
-40 °C ... +85 °C
Humidity
10 … 95% relative humidity, no condensation permitted
Environmental
Conditions
Environment
For UL compliant usage: The device must be used in a
pollution degree 2 environment.
CIFX 90E-DP\F
1, 2
,
CIFX 90E-DP\MR\F
2
CIFX 90E-DP\NHS\F,
CIFX 90E-DP\ET\F,
CIFX 90E-DP\MR\ET\F
51 x 30,2 +/- 0,1 x 11 mm
51 x 30,2 +/- 0,1 x 12,5 mm
Dimensions (L x W x H)
2
Beginning with hardware revision A: 51 x 30,2 mm + 0,1
/ - 0,1 mm x 11 mm; [W = 30,1mm ... 30,3 mm: The
printed circuit board (PCB) has become wider on the right
side by 0.1 mm … 0.3 mm, thus deviating from the norm].
1
For hardware revision 9: 51 x 30,2 x 11 mm; [W = 30,2
mm: The printed circuit board (PCB) has become wider
on the right side by 0.2 mm, thus deviating from the
norm].
For further details on the elelment hights refer to section
Notes on the Card Height - PC Card cifX Mini PCI and
Mini PCIe
on page 59.
Mounting/Installation
PCI Express Mini System Connector (3.3 V),
X1/X2
= One Lane, refer to section
Cards cifX Compact PCI, Mini PCI, Mini PCIe, PCI-104
page 58.
Device
RoHS Yes
CE Sign
Yes
Emission
EN 55011:2009 + A1:2010, CISPR 11:2009, Class A
(Radio disturbance characteristics - Limits and methods
of measurement)
CE Sign
Immunity
EN 61000-4-2:2009 (Electrostatic discharge test)
EN 61000-4-3:2006 + A1:2008 + A2:2010 (Radiated,
radio-frequency, electromagnetic field test)
EN 61000-4-4:2004 + A1:2010 (Burst Electrical fast
transients/burst test)
EN 61000-4-5:2006 (Surge test)
EN 61000-4-6:2009 (to conducted disturbances, induced
by radio- frequency fields)
EN 61000-4-8:2010 (power frequency magnetic field test)
EN 61000-6-2:2005 + B1:2011 (for industrial
environments)
UL Certification
The device CIFX 90E-DP\F is
certified according to UL 508
UL-File-Nr. E221530
Configuration Software
Master and Slave
SYCON.net
Configuration
Configuration Software Slave
netX Configuration Tool