Technical Data
182/299
PC Cards cifX Compact PCI, Mini PCI, Mini PCIe, PCI-104 | Installation, Operation and Hardware Description
DOC120205UM53EN | Revision 53 | English | 2019-03 | Released | Public
© Hilscher, 2008-2019
CIFX 90-CO\F
Parameter
Value
RAM
8 MB SDRAM
FLASH
4 MB serial Flash EPROM
Integrated Memory
Size of the Dual-Port Memory
64 KByte
Bus Type
Mini PCI, according to [bus spec 5], refer to section
Pin Assignment for Mini PCI Bus,
Transmission Rate
33 MHz
Data Access
DPM or DMA (Direct Memory Access)
System Interface
Width for the data access to the
Dual-Port Memory (DPM)
32-Bit
CANopen
Communication
Supported communication
standard/ protocol (determined by
the loaded firmware)
CANopen Master,
CANopen Slave
Transmission rate
10 kBit/s, 20 kBit/s, 50 kBit/s, 100 kBit/s, 125 kBit/s,
250 kBit/s, 500 kBit/s, 800 kBit/s, 1 MBit/s
Interface Type
ISO-11898, refer to section
CANopen detached Network
Interface
AIFX-CO, refer to section
, page 230.
Important!
Operating the PC card CIFX 90-CO\F requires proper
connection of the CANopen detached network interface (AIFX-
CO) to the basic card!
CANopen Interface
Connector AIFX-CO
Connector Fieldbus X3
(JST 10FMN-SMT-A-TF(LF)(SN), Pitch 1,0 mm)
SYS
System Status LED
Display LED
Display
For LEDs at AIFX-CO, refer to section
, p. 230.
Supply Voltage
+3.3 V dc ±5 %, refer to section
Current consumption at 3.3 V
650 mA (maximum)
Power supply
Connector
Via Mini PCI Bus
Operating temperature range*
-20 °C ... +70 °C
(
acc. to UL: 0 °C ... +70 °C
)
*Air flow during measurment
0,5 m/s
Storage temperature range
-40 °C ... +85 °C
Humidity
10 … 95% relative humidity, no condensation permitted
Environmental
Conditions
Environment
For UL compliant usage:
The device must be used in a pollution degree 2
environment.
Dimensions (L x W x H)
60 x 45 x 11 mm
Mounting/Installation
Mini PCI Socket (3.3 V), Type III System Connector,
refer to section
Slot for the PC Cards cifX Compact PCI,
Device
RoHS Yes
CE Sign
Yes
Emission
EN 55011:2009 + A1:2010, CISPR 11:2009, Class A
(Radio disturbance characteristics - Limits and methods of
measurement)
CE Sign
Immunity
EN 61000-4-2:2009 (Electrostatic discharge test)
EN 61000-4-3:2006 + A1:2008 + A2:2010 (Radiated,
radio-frequency, electromagnetic field test)
EN 61000-4-4:2004 + A1:2010 (Burst Electrical fast
transients/burst test)
EN 61000-4-5:2006 (Surge test)
EN 61000-4-6:2009 (to conducted disturbances, induced
by radio- frequency fields)
EN 61000-4-8:2010 (power frequency magnetic field test)