Technical Data
202/299
PC Cards cifX Compact PCI, Mini PCI, Mini PCIe, PCI-104 | Installation, Operation and Hardware Description
DOC120205UM53EN | Revision 53 | English | 2019-03 | Released | Public
© Hilscher, 2008-2019
CIFX 90E-2DP\DN\ET\F,
CIFX 90E-2DP\DN\MR\ET\F
Parameter
Value
with cable connector Fieldbus X3
and
X4,
- PROFIBUS detached network interface (AIFX-DP) and
- DeviceNet detached network interface (AIFX-DN).
Note:
The device height and the power input of the PC Card Mini
PCI Express CIFX 90E-2DP\DN\ET\FF and CIFX 90E-
2DP\DN\MR\ET\F do not comply with the standard specifications.
Function
Communication Interface with Mini PCI Express,
1 x PROFIBUS interface and 1x DeviceNet interface
Communication
Controller
Type netX
100
processor
RAM
8 MB SDRAM
FLASH
4 MB serial Flash EPROM
Size of the Dual-Port Memory
64 KByte
Integrated Memory
MRAM (only CIFX 90E-
2DP\DN\MR\ET\F)
128Kbyte (= 64K Words);
Note:
Using the cifX Device Driver (from Version 1.1.1.0)
access to this memory is possible and it can be used as a
remanent memory.
Bus Type
Mini PCI Express One Lane Port, according to [bus
spec 2] and [bus spec 6], refer to section
, page
165 and
Pin Assignment for Mini PCI Express Bus / SYNC
Transmission Rate
33 MHz
Data Access
DPM or DMA (Direct Memory Access)
System Interface
Width for the data access to the
Dual-Port Memory (DPM)
32-Bit
PROFIBUS
Communication
Supported communication
standard/ protocol (determined by
the loaded firmware)
PROFIBUS DP Master,
PROFIBUS DP Slave
Transmission Rate
9,6 kBit/s, 19,2 kBit/s, 31,25 kBit/s, 45,45 kBit/s,
93,75 kBit/s, 187,5 kBit/s, 500 kBit/s, 1,5 MBit/s,
3 MBit/s, 6 MBit/s, 12 MBit/s
Interface Type
RS 485, refer to section
page 154.
PROFIBUS detached Network
Interface
page 229.
Important!
Operating the PC card CIFX 90E-2DP\DN\ET\FF or
CIFX 90E-2DP\DN\MR\ET\F requires proper connection of the
PROFIBUS detached network interface (AIFX-DP) and of the
DeviceNet detached network interface (AIFX-DN) to the basic
card!
PROFIBUS interface
Connector AIFX-DP
Cable Connector Fieldbus
X3
(JST 10FMN-BMT-A-TF(LF)(SN), Pitch 1,0 mm)
DeviceNet
Communication
Supported communication
standard/ protocol (determined by
the loaded firmware)
DeviceNet Master,
DeviceNet Slave
Transmission rate
125 kBit/s, 250 kBit/s, 500 kBit/s
Interface Type
ISO-11898 according to DeviceNet specification,
refer to section
DeviceNet detached Network
Interface
page 231.
Important!
Operating the PC card CIFX 90E-2DP\DN\ET\FF or
CIFX 90E-2DP\DN\MR\ET\F requires proper connection of the
PROFIBUS detached network interface (AIFX-DP) and of the
DeviceNet detached network interface (AIFX-DN) to the basic
card!
DeviceNet Interface
Connector AIFX-DN
Connector Fieldbus
X4
(JST 10FMN-SMT-A-TF(LF)(SN), Pitch 1,0 mm)
SYS
System Status LED
Display LED
Display
For the LEDs at AIFX-DP at channel X1, refer to section