Technical Data
244/299
PC Cards cifX Compact PCI, Mini PCI, Mini PCIe, PCI-104 | Installation, Operation and Hardware Description
DOC120205UM53EN | Revision 53 | English | 2019-03 | Released | Public
© Hilscher, 2008-2019
Parameter
Description
Reference to firmware/stack version
V2.6
Table 178: Technical Data PROFINET IO RT Controller Protocol
10.4.11 PROFINET IO-Controller (V3)
Parameter
Description
Maximum number of ARs (Application
Relation)
128 for RT communication
64 for IRT communication
Maximum number of cyclic input data
5652 bytes, including provider and consumer status
Maximum number of cyclic output data
5700 bytes, including provider and consumer status
Send clock
1 ms, 2 ms, 4 ms for RT mode
250 µs, 500 µs, 1 ms, 2 ms, 4 ms for IRT mode
Performance limits of ARs
Max. 8 ARs, if a send clock < 500 µs
Max. 16 ARs, if a send clock < 1 ms
Max. 64 ARs, if a send clock < 2 ms
Maximum number of submodules
2048
Maximum amount of data per IOCR
1440 bytes
Number of IOCRs per AR
1 Input IOCR
1 Output IOCR
Maximum amount of data for acyclic
read/write record access
65536 bytes
Maximum amount of record data per AR
16384 bytes
Alarm processing (configurable)
Stack processes alarms automatically
Applikation processes alarms
Maximum number of ARVendorBlock
256
Maximum size of ARVendorBlockData
512 bytes
Device Access AR CMI Timeout
20 s
Functions
Automatic Name Assignment
Media Redundancy Client
Media Redundancy Manager (requires license)
DCP function API
Name Assignment IO-Devices (DCP SET NameOfStation)
Set IO-Devices IP (DCP SET IP)
Signal IO-Device (DCP SET SIGNAL)
Reset IO-Device to factory settings (DCP Reset FactorySettings)
Bus scan (DCP IDENTIFY ALL)
DCP GET
PROFINET specification
Implemented according to V2.3 ED2 MU3
Legacy Startup supported according to PROFINET specification V2.2