This menu gives the user access to the programmable parameters that affect the management
of the passage detection system, door movement, time outs and interface signals from/to the
external world. Refer to the ‘Parameters Programming Manual’.
Automatic Testing
The logic system of the Unit performs a looped test of the operating status of the motors,
photocells and batteries (if installed). If a fault occurs:
•
A buzzer generates an intermittent signal.
•
At the same time, the traffic lights and pictograms flash displaying a red cross.
•
On the GC01 display a message appears indicating the specific condition.
•
The fault output is activated.
•
The readers are de-activated.
•
A message is transmitted via the RS485 serial line regarding the type of fault
detected.
If a fault occurs, contact the maintenance personnel for assistance.
The alarms corresponding to the different tests cause the activation of the fault output.
The activation of that output can be delayed by means of a programmable parameter.
It is possible to mask each one of the alarms in order to avoid the fault output activation when
it occurs.
The programmable parameters regarding these operations are collected into the “Diagnostic
Group” (see the annex “Parameter Table”).
Automatic Motor Testing
The Motor Board is composed with many devices which work together in the motion process.
When a given component breaks whether it is the encoder, the power driver or any other
component the result is a possible loss in motion control and a consequently dangerous situation
for a user in transit.
The diagnostic of the Motor board together with a door’s force limitation, control and obstacle
detection, allows it to manage these faults in compliance with the CE / UL requirements to reduce
the risk of a danger impact.
What follows is a series of diagnostic run-time tests to detect any irregular behaviour in the
motion process:
1.
If a zero setting cycle detects a lower angle range the Motor Board will go in fault.
2.
If more than five consecutive obstacles are detected the Motor board goes in fault.
3.
If an open or close command takes more than 15 seconds to complete the gate
goes in fault.
4.
If the absolute switch position signals a door transit when no motion command is
pending the Motor board goes in fault.
5.
If the motor is powered continuously for more than 3-4 seconds, an independent