119
Appendix
Declar
ation
Spar
e P
ar
ts
Main
tenance
Insta
llation
Technica
l Inf
ormation
Instruc
tions f
or use
pr
oduc
t Description
In
tr
oduc
tion
Con
ten
ts
Oper
ation & Main
tenance Manual SpeedStile B
P DS
Fig 8.10 - Remote Control, Emergency Echo and Emergency Command
M2 Remote Control GC01
M3 Alarms GC01
1
+24 V
DC
5,6
Emergency echo Output
2
Free Mode Direction A
M4 Emergency GC01
3
Locked Mode Direction A
With W12 jumper in:
4
Free Mode Direction B
1
Do not use
5
Locked Mode Direction B
2
Emergency Input
6
NC / NO Aisle Mode
(GND available in M2 connector, pin 7 and
8) with W12 jumper off:
7
GND
1
+ Emergency command
8
GND
2
- Emergency command
Remote Control Commands
Pin 2 Pin 3 dir.A mode
Pin 4 Pin 5 dir.B mode
Pin 6 Aisle mode (*)
H
H
Controlled
H
H
Controlled
H
NO
L
H
Free
L
H
Free
L
NC
H
L
Locked
H
L
Locked
(*) Long version only