That redundant protection is bypassed when the B12 copper jumper is cut off (see “Table: MB01
Jumpers Factory Setting” - Appendix B).
Transit
Introduction
The command logic manages all the system actions, which allows a person to move through
the passageway. The logic uses all the in-formation from the photocells to detect the presence and
position of persons during the transit.
In addition, it receives permissive signals from the readers and at the same time, provides the
readers with activation and transit completed signals, it controls and regulates movement of the
mechanisms and effects all related acoustic and visual warnings.
Hold Open / Hold Close
This state is defined with the ‘Hold Open, Close’ parameter from the Control Board on the
connector M5. The default value of the parameter is ‘Enable’.
•
Main-menu/Setup/IO/Hold Open, Close
If it’s ‘ENABLE’:
-
The function ‘Hold Close’ has priority, if both inputs are enabled.
-
The panels open and stay opened, if the ‘Hold Open’ input is enabled.
-
The panels close and stay closed, if the ‘Hold Close’ input is enabled.
-
The GC01 displays:
M5
HOLD OP/CL
M4
24Vdc
This requires 24 Vdc from the M4 terminal.