Safety Photocells Management
Introduction
The SpeedStile BP DS is equipped with either one or (optional) two safety photocells which, are
installed in between the doors, to prevent the user from being hit by the panels when closing.
Fig 4.4 – Safety Photocells Disposition
Safety RX1
Increasing the Safety Area
The user is able to program several transit photocells so that they also act as safety photocells,
increasing the total safety area recognized by the gate.
The user can also program two different areas:
•
One for a Normal transit.
•
One for an Wide (900 mm Passage Way) transit (see section “Operating Modes”).
Remember that although the added photocells act as safety photo-cells they are not tested
along with the default safety photocell so their working state cannot be guaranteed at any
moment unlike the RX1 safety photocell (see section “Diagnostic Menu - Photocells Diagnostic”).
To add sensors to the safety area base pattern, there is a menu dialogue which provides an easy
graphical tool:
•
Main-menu/Setup/Safety/Safety Zone STD for a Normal transit.
•
Main-menu/Setup/Safety/Safety Zone WIDE for an Wide transit.