Table For Hold Open/Close
MBO1 M5 - M4 Hold Open / Close
Pin
M5 Terminal
M4 terminal
Connection
details
1
Hold Open +
+24Vdc
Users control
2
GND
GND
Linked pins
3
Hold Close -
-24Vdc
Users control
4
GND
GND
Linked pins
Validation
In this case, the user must validate within a time out period that depends on which corridor
zone is engaged.
In the picture below, an example of the zones pattern is given in A direction. The same for B
direction must be considered. The parameter “Access Level” defines all the possible configurations
for Zone 1 and Zone 2 for the Short or Long Cabinet depending on what has been selected. This
parameter adjusts the transit velocity of the passengers.
There are two time-outs, one for the Zone 1 and one for the Zone 2. The time-out for Zone 1 is
higher than Zone 2.
The tailgating alarm only uses the sensors configured in Zone 2.
Examples:
- If the parameter “Access Level” is equal to the first sensor after the doors,
only the Zone 1 is active and the tailgating alarms are disabled; anyway the
intrusion alarms are enabled.
-
if “Access Level” is equal to 1, the passenger must validate before entering into
Zone 2 and the tailgating alarms are enabled; the passenger flow rate is slower.
-
if “Access Level” is equal to 7 for the long cabinet, the passenger must validate
before going past the doors; the TAILGATING is detected only when the passenger
is beyond the doors; the passenger flow is higher.
•
Main-menu/Setup/Fraud/Access Level