60
In
tr
oduc
tion
Pr
oduc
t Description
Instruc
tions f
or use
Technica
l Inf
ormation
Insta
llation
Main
tenance
Spar
e P
ar
ts
Appendix
Con
ten
ts
Declar
ation
Oper
ation & Main
tenance Manual SpeedStile B
P DS
Display
Meaning
Appears in case of power fail. When the MB01 switches off,
appears:
Failure of some device into the motor control circuit.
After MB01 reset, if TR1 is in position 0-4, this is an error
condition: the mechanism is not yet selected!
After MB01 reset, if TR1 is in position 0, this is an error condition.
The learn procedure is required and has not yet been executed!
Fig 4.16 – MB01 LEDs
LED
Description
DS1
Red
‘FAULT’ – on if the redundant supervisor circuit is cutting
the motor current.
DS2
Green
not used.
DS3
Green
on when the safety transmitter is ON.
DS4
Green
on when the safety sensor in free.
DS5
Green
not used.
DS6
Red
“WD” – on when the watch dog is cutting the motor
current.
DS7
Red
“LIMIT” – on when the motor current reaches the
limitation circuit threshold.