32
In
tr
oduc
tion
Pr
oduc
t Description
Instruc
tions f
or use
Technica
l Inf
ormation
Insta
llation
Main
tenance
Spar
e P
ar
ts
Appendix
Con
ten
ts
Declar
ation
Oper
ation & Main
tenance Manual SpeedStile B
P DS
Fig 4. 5 – Adding Safety Photocells Dialogue
0 * < * 0
0 < 0
SW1
SW2
SW3
RESET
In the figure above is shown the dialogue menu to set the safety pattern. With the keys SW2
and SW3 the user can point to a particular photocell (indicated by an arrow); after pointing to a
photocell the user can add or remove that photocell to the safety pattern by pressing the SW1 key.
If a photocell is shown as “O” it means that it is not currently part of the safety area.
Instead if a photocell is shown as “
*
” it means that it is configured as a safety photocell. For
example in the picture only two photocells are added to the base pattern; this is also the default
setup for SpeedStile BP DS range.
How Does the Safety Area Works
The reaction of the gate when the safety area is obscured is de-pendent on if the gate is in
running mode or in another state, i.e. in maintenance or out of service.
Safety Management in Running Mode
When the gate is in Running Mode the safety area is composed by the default safety photocells,
RX1, and, if programmed, the added transit photocells. This area can operate in Opening or in
Closing depending on a programmed parameter.
Closing Doors
•
If the safety area is engaged before a programmed percent-age of closing ,the
panels still continue to close.
•
After Pc if the safety area is still obscured then the panels are opened the panels
now remain open until the safety area is cleared.
•
When the safety area is released, after a programmed time-out the panels restart
to close.
Pc expressed in % where 100% is equal to a complete doors closing:
•
Pc = Main-menu/Setup/Safety/STD Shadow position for a Normal transit.
•
Pc = Main-menu/Setup/Safety/WIDE Shadow position for a Wide transit.
Tc expressed in 128 ms unit:
•
Tc = Main-menu/Setup/Safety/STD Safety time to re close for a Normal transit.
•
Tc = Main-menu/Setup/Safety/WIDE safety time to re close for a Wide transit.