Symptom
Check
Action
Panels do not drive
Check mains input voltage
and 24 VDC supply on logic
boards
Replace transformer
Fuses on all three logic boards
Replace as required
Increase back-off sensitivity
If F1 fuse has blown motor
may be permanently damaged
Check functionality of all the
logic boards on each electrical
plate, especially MB01 drive
cards
Re Flash Firmware
Perform a re learn
Replace as required
Card reader inputs
Remove card reader
connections and link across
the inputs
Unit alarms
Photocells, perform diagnostic
test using GC01 to check that
all the photocells are working
Replace faulty photocell(s) if
required
Check brackets
Battery back up
If fitted the cells may be in
need of replacement. If they
are not fitted the self-test
function should be disabled
by changing the relevant
parameter
Check looms
Panels do not close after
transit
Safety photocell
Replace if required
Panel(s) do not back off when
obstructed
Trimmer on MB01 drive card
Tune the obstacle sensitivity.
Replace MB01
Panel(s) pulses when in open
or close position
Trimmers on MB01 drive card
Tune the offsets.
Replace drive card if required
Panel(s) do not open and close
correctly
Trimmers on MB01 drive card.
Launch the learning
procedure.
Replace drive card if required
Encoders
Replace if required
Check encoder mounted
correctly
Check looms
Check Mech setting