Using the SpeedStile BP DS
The SpeedStile BP DS is unlocked by presenting a personalised identity card or device to the
access control reader, (Supplied by others). It can also be unlocked by depressing a button on the
casework or remote reception push button, if fitted, enabled for Free Passage. This will activate the
mechanism and retract the panels into the casework, rendering the SpeedStile BP DS ready for use
by walking through the walkway passage in the authorised direction.
Should the user decide not to proceed with the passage, the SpeedStile BP DS will remain
unlocked for a predetermined time after which it will ‘time out’ and reset the unit making it
available for the next person.
After the passage is complete the mechanism will be reactivated automatically to operate the
panels to the closed position.
Always check the PCW's (Picto chevron way mode) mounted on the frontal lid of the SpeedStile
BP DS casework (if fitted) for right of passage, i.e.
Red Cross
denotes opposite direction has right of
way or
Green Tracing
denotes right of way.
Should the SpeedStile BP DS be used in the incorrect manner, i.e. (incorrect transit )the panels
will close and an alarm sounds. Do not panic, retreat from the walkway, and wait for the alarm to
stop and the system to reset automatically. During the alarm stage the status lights will flash, after
reset check the status lights for right of passage.
Do not attempt to follow a person through the SpeedStile BP DS if you do not have an
authorisation. This is known as Tailgating, and will activate the controller to close the gates
between the authorised and unauthorised user. The SpeedStile BP DS will now go into the alarm
and reset phase.
If the SpeedStile BP DS and access control system has been configured for multiple
authorisations, known as Stacking, the users may proceed in close proximity after the preceding
passage occupant. The transit is correct without alarms when the distance between the passengers
is greater than 300 mm. Again, the pictogram lights should be checked for right of way.
Should the SpeedStile BP DS be set up for free passage, there is no need to wait for any
authorisation; the passage may be freely used. Again, check the PCW's for right of way, in
normal operation the opposite passage will be activated via the access control device requiring
authorisation.
Emergency / Fire Alarm
The SpeedStile BP DS can be configured to fully open the panels when an Emergency / Fire
Alarm are given to the controller by the appropriate detection system (by others).
This condition will remain for the duration of the signal being received by the controller.
Power Failure
Should the power fail during operation, or dormant use, the panels will remain in their position
at the time of power failure. They can only be opened by removing the side access panel and
pushing the cantilever arm.
A Battery Back Up option is available at extra cost and this will operate the SpeedStile BP DS to
complete or commence an operating cycle to the configured Fail State. The Fail State is configurable
via programmable parameter (see “
System Group
” in the annex “Parameter Table”).