Oper
ation & Main
tenance Manual SpeedStile B
P DS
Safety
The SpeedStile BP DS passage is protected via a safety photocell so that when a presence is
detected the panels will not operate until the presence is removed. In this condition the SpeedStile
BP DS may be go into Out Of Service Mode.
Should an obstacle be detected during the closing of the panels they will back off to the open
position. In this condition the SpeedStile BP DS will automatically go into Alarm condition.
I
mportant
n
ote
-
do not
walk
through
the
BarrIer
wIth
large
BagS
or
BrIefcaSeS
In
front
,
or
traIlIng
BehInd
you
. c
arry
them
In
a
normal
manner
,
next
to
the
Body
.
do not
drag
BagS
over
the
caSework
top
.
a
ctIvatIon
of
any
remote
command
or
SerIal
lIne
command
haS
prIorIty
over
the
SettIng
made
uSIng
the
programmaBle
parameterS
.
Operating Modes
The SpeedStile BP DS operation is bidirectional. The two passageway directions A (the master
casework is at the right hand of the user) and B can be managed in one of the following modes:
•
Free:
The gate enables transit of all passengers in the
corresponding direction, the entry and/or exit
PCW's have green chevrons.
•
Blocked:
The gate does not enable transit in corresponding
direction, entry and/or exit PCW's have
the red cross.
•
Controlled:
The gate allows transit only to persons authorized by the
access control system.
•
Normally Closed:
In standby, the gate presents itself to the user with the
door closed.
The operating mode of the gate can be set by means of:
•
Gate itself (on failure, etc.).
•
Programmable relays between Control Board switches.
•
RS485 serial line (for more details see section “Serial 485 Protocol”).
•
Parameters saved into a file from a Personal Computer and up-loaded on the
GC01 Control Board (see section “Up-load/Download Parameters “in the annex
“Parameter Table”).
•
Loader for a remote upgrade of the Firmware.
•
Remote command on the provided I/O.
•
Wide (900 mm Passage Way) transit (for more details see section “Increasing the
Safety Area”).The priority on activation of the remote command or serial line
command is set by a programmable parameter (see “System/Serial 485 Group” in the annex
“Parameter Table”).
In case of serial line command priority, other programmable parameters assign the operating