The Readers can be enabled or disabled by parameters:
•
Main-menu/Setup/Reader/Reader A status for Reader A.
•
Main-menu/Setup/Reader/Reader B status for Reader B.
If the Reader is disabled the User will not be able to validate.
If the Reader is ENABLED the status of the Reader will depend on several conditions.
The actual status of the Readers in any moment will be indicated by two flags:
•
Reader A enable flag, for Reader A.
•
Reader B enable flag, for Reader B.
Readers Input Programming's
The SpeedStile BP DS provides twelve inputs each one programmable to be addressed to one of
the Readers triggers (for more details see section “Interface Inputs and Outputs”).
Validation Process
The SpeedStile BP DS offers two different ways to process the reader authorisations during an
alarm condition due to either a tailgating attempt or intrusion because of unauthorised passenger
inside the gate.
‘reader disabled’ mode:
The logic ignores any new authorisation until the gate
aisle comes free and the alarm is cancelled.
‘reader enabled’ mode:
When a new authorisation is received, it is memorised
and, in this case, processed immediately stop-ping the
alarm.
The first option is preferred if the security aspect is prior on the flow speed. In that case, people
must be trained on the use of the SpeedStile BP DS.
The second option allows speeding up the flowing of passengers through the gate when it is
used by people without any specific knowledge of that appliance.
The mode is determined by a programmable parameter of the “Reader Group” (see the annex
“Parameter Table”).
To increment the stack of the Reader and to gain the passage authorization the user has to
signal a proper input addressed to the Reader (A or B depending on the side where the user is). This
is the validation process. The validation process isn’t allowed in any situation:
•
Validation when in Fraud alarm.
During a fraud alarm the user is permitted to validate
If the parameter Main-menu/Setup/Reader/State on alarms is programmed as “ENABLED”.
If the parameter is programmed as “DISABLED”, the Readers (both readers) will be disabled.
The reader will be disabled until the Aisle is busy
if the parameter Validation type is programmed as “Out-Validation”.