M6 ‘READER OPTO IN’
3
reader A authorisation
- wide
reader B authorisation
- wide
rated input voltage 24 VDC;
11 mA @ 24 VDC
4
GND
GND
MB01 Addressable Outputs
M8 ‘READER OUT’
Pin
Master Side
Signal (*)
Slave Side
Signal (*)
NC/NO
Jumper
Relay
LED
1, 2
Gate Busy A
Gate Busy B
W5
K4
DS15
3, 4
Ack A Reader
Ack B Reader
W4
K3
DS14
5, 6
Reader A Enable
Reader B Enable
W3
K1
DS12
7, 8
Ack Count A
Ack Count B
W2
K2
DS13
(*) operation depends on parameters configuration
Input Programming
The Inputs can be programmed to be linked to a Reader, whether A or B, or to be programmed as
the Fire Alarm inputs.
To program the inputs:
•
Enter the menu Main-menu/Setup/IO;
•
If the input to be programmed is on the GC01 board then select the Control Board
sub-menu.
•
If the input to be programmed is on the MB01 master board then select the Master
Board sub-menu.
•
If the input to be programmed is on the MB01 slave board then select the Slave
Board sub-menu.
Select the input to be programmed; any input can be programmed as:
1.
READER –A:
will be linked to the Reader A inter-face, trigger for a
normal passage.
2.
WIDE READER –A:
will be linked to the Reader A inter-face, trigger for an
Wide passage.
3.
READER –B:
will be linked to the Reader B inter-face, trigger for a
normal passage.
4.
WIDE READER –B:
will be linked to the Reader B inter-face, trigger for an
Wide passage.
5.
FIRE ALARM:
will be linked to the Fire Alarm functionality. See the
“Emergency” section below for more details