tenance Manual SpeedStile B
P DS
Every time the gate is powered, the MB01 needs to make this zero setting before being able to
move normally.
The process will be done in Running Mode and not in Maintenance Mode as in the former.
The logic interrupts the zero setting cycle if:
•
The emergency command is given.
•
The gate is equipped with batteries and the main power fails.
•
One or more of the four sensors close to the glass panels are engaged (see section
“Safety Photocells Management”).
n
ote
-t
he
zero
SettIng
cycle
reStartS
once
the
oBStructIon
IS
cleared
.
In Running Mode- The zero settings will start to close reaching the close limit position and to
open reaching the open limit position.
If the zero settings have not been configured a ‘c’ will be displayed (see
section “MB01 Messages and LEDs”).
If the Zero settings cycle is running, both ‘f’ and ‘b’ will be the same time
displayed (see section “MB01 Messages and LEDs”).
In Maintenance Mode
Several cycles take place after the first close/open,
because in Maintenance the absolute position
sensor switch also has to be learned.
n
ote
-I
f
the
zero
SettIngS
faIlS
,
the
Board
goeS
In
f
ault
condItIon
(
See
SectIon
“S
how
out
of
S
ervIce
u
tIlIty
”)
and
only
a
h
ard
reSet
can
clear
thIS
State
. I
n
fault
the
engIne
wIll
Be
unaBle
to
move
any
more
.
Mechanism Speed
The gate panel speed is regulated with two trimmers on the MB01 board, TR2 trimmer for the
closing speed and TR3 for the opening speed. Each trimmer has six different settings.
The speed range covered by all the positions of the TR2 and TR3 trimmers allows, for each kind
of mechanism, the compliance with
EN 12650
limits of the impact force.
n
ote
1-t
he
mechanISm
Speed
IS
the
maIn
factor
for
the
lImItatIon
of
the
Impact
force
In
caSe
of
collISIon
wIth
an
oBject
.
n
ote
2- a
fter
tr2
or
tr3
trImmer
poSItIon
IS
changed
,
the
new
poSItIon
BecomeS
effectIve
only
after
repeatIng
the
learnIng
procedure
.
Содержание SpeedStile BP DS Standard Lane
Страница 1: ...S P E E D S T I L E BP DS series Operation Maintenance Manual...
Страница 2: ......