background image

NV5 Installation Instructions

NV5-EI02 - 09/2019

Please read all installation instructions before installing the unit.

Figure 1: NV5 Back Plate

 1. Select detector location using Figure 2 as a guide. The detector must be installed at 

2.1m (7.0 ft) or higher.

Figure 2: Beam Pattern

 2.  Loosen the locking screw (9), located at the bottom of the unit.
 3.  Separate the front cover from the back plate.
 4.  Separate the PCB board from the back plate
 5.  On the back plate drill holes for the wire pass-thru (2) and appropriate knockout holes.            

For wall mount drill holes (3), (10) and (15).    
For corner mount drill holes (5), (7), (12) and (14).     
For bracket mount drill hole 

(

4).

 6.  Secure back plate to surface.

For wall mount, pass wires through hole (2) of the back plate and secure with screws at 
(3), (10) and (15).
For a corner mount, pass wires through hole (2) of the back plate and secure with 
screws at (5), (7), (12) and (14).

Figure 3: SB100 Bracket Assembly Installation

For bracketed ceiling mount (with SB100), insert ceiling accessory (21) and orient as 
per (23). Insert the Bracket Retainer (25).Pass wire from ceiling through(25),through 
(17) and through hole (2) of the back plate. Secure bracket to ceiling with screws at 
(16). Secure back plate with a screw at (4) onto bracket at (18). 
For bracketed wall mount (with SB100), insert wall accessory (22) and orient as per 
(24). Pass wire from wall through (25), through (20) and through hole (2) of the back 
plate. Secure bracket to wall with screws at (16) Secure back plate with a screw at (4) 
onto bracket at (19).

 7.  Snap the PCB board onto the back plate.
 8.  Connect wires to terminal board (1) as per Figure 4.   

Figure 4: Terminal Board Wiring

Callout Description

16

Bracket mounting holes

17

Wire pass-thru (ceiling)

18

Ceiling mount

19

Wall mount

20

Wire pass-thru (wall)

21

Ceiling Accessory

22

Wall Accessory

23

Ceiling Accessory 

Orientation

24

Wall Accessory Orientation

25

Bracket Retainer

ALARM OUTPUT

N.C. COM BLK RED TAMPER

12 Vdc

N.C.

Callout Description

1

Terminal board

2

Wire pass-through

3

Wall mount (knockout)

4

Bracket mount (knockout)

5

Corner mount (knockout)

6

Trimpot (sensitivity 1-5)

7

Corner mount (knockout)

8

Tamper switch

9

Locking screw

10

Wall mount (knockout)

11

Sensor

12

Corner mount (knockout)

13

Jumpers (profile/LED)

14

Corner mount (knockout)

15

Wall mount (knockout)

Отзывы: