Connection Chapter Three CNC Device Connection
148
Chapter Three CNC Device Connection
3.1
X1 Communication Interface
GSK928TE
Ⅱ
CNC and the external PC
(
RS232 interface
)
or GSK928TE
Ⅱ
CNC(X1 interface)
are connected by the communication interface(X1), and exchange or transmit the data.
3.1.1 X1 Signal
5:GND
3:TXD
2:RXD
3.1.2 Specification
●
Level
:
standard RS232 level
●
Communication baud rate
:
9600bps
3.1.3 Connect with the External PC by RS232 Interface
CNC device
5
GND
PC
RS232
TXD
RXD 2
3
PE
5
X1
2
3
GND
RXD
TXD
Cable length<15m
When the data is exchanged between the CNC and PC, it must equipped with our
communication software.
The communication cable length is not more than 15m, otherwise, which may cause the
transferring data distortion.
3.1.4 Connect with Another GSK928TE
Ⅱ
CNC by RS232 Communication Interface(
(
X1
)
P in
Name
Remark
Direction
1 NC
2 RXD Data
receive
3 TXD Data
transmit
4 NC
5 GND
6 NC
7 NC
8 NC
9 NC