Connection Chapter Three CNC Device Connection
160
Connection layout between GSK928TE
Ⅱ
CNC and GSK DA98 AC servo drive unit
GSK928TE
Ⅱ
(X) DA98 drive unit
3 Xpu-
11 Xpu+
5 Xdir+
13 Xdir-
7 Xen
10 0V
18 PULS
6 /PULS
19 SIGN
7 /SIGN
21 SON
8 COM+
15 ALM
3 COM
Pulse (X+)
Pluse (X-)
Direction (X+)
Direction (X-)
Enabling (X)
Metal shell
1 Xalm
5 COM
Alarm (X)
+24V
2 +24V
Metal shell
10 RSTP
4 DG
17 DG
22 FSTP
5 X0
2 Zero
X4 toolpost socket
GSK928TE
Ⅱ
(Z) DA98 drive unit
12 ZPU+
4 ZPU-
6 Zdir+
14 Zdir-
15 Zen
10 0V
6 /PULS
18 PULS
19 SIGN
7 /SIGN
21 SON
15 ALM
8 COM+
3 COM
Pluse (Z+)
(Z+)
Pulse (Z-)
Alarm (Z)
Enabling (Z)
Direction (Z-)
Metal shell
9 Zalm
2 +24V
5 COM
+24V
Metal shell
10 RSTP
4 DG
17 DG
22 FSTP
13 Z0
2 Zero
X4 toolpost socket
When the stepper motor is used, set the parameters of GSK928TE
Ⅱ
according to the specific
condition, including P5, P6, P11 (D6, D7), P12 (D5, D6), P17, P18, P19, P20, P21, P22. For
definitions of parameter, see
Operation
,
Parameter.
The shield cable must be used to connect the step driver and CNC system, otherwise cause that
the motor steps out owing to the external interference.
CNC system, the stepper driver and the stepper motor must be reliably connected with the
earthing to avoid the motor stepping out because of the external interference.
3.5.7 Connecting GSK928TE
Ⅱ
CNC and Panasonic Drive Unit
Connecting GSK928TE
Ⅱ
CNC and Panasonic MINAS V serial drive unit
Содержание GSK928TE
Страница 1: ...GSK928TE II Turning Machine CNC System User Manual...
Страница 117: ...Programming Chapter Three Commands and Functions 112 G99 G01 X50 Z30 F0 2 G04 D2 G99 G01 X50 Z30 F0 2...
Страница 148: ...GSK928TE Turning CNC System User Manual 143 Connection Chapter One Interface 1 1 Interface Layout...
Страница 185: ...Connection Appendix 180 J3 1 AC220V J3 2 0V...