![GSK GSK928TE Скачать руководство пользователя страница 169](http://html1.mh-extra.com/html/gsk/gsk928te/gsk928te_user-manual_2275225169.webp)
Connection Chapter Three CNC Device Connection
164
3.6.2 Technology specification
●
Photoelectric couple technology with max. isolation voltage 2500VRMS
●
Supply voltage 24V
3.6.3 The normally open contact of mechanical contact switch or the electric proximity switch
without the contact( the contact is proximal, it is the LOW) are used for DecX
,DecZ,
-XZL,
+XZL,
X0,
Z0,
M91,
M93,
SHL,
M3XZ1,
M3XZ2.
Interface method:
3K
CNC side
It is connected when
the signal is valid
+24V
0V
4.7K
Or
3K
CNC side
Machine side
+24V
0V
3.6.4 SP, ST signals use the normally open contact of mechanical contact switch; ESP with the
normally-closed contact of self-lock mechanical contact switch.
Connection method
:
+24V
2K
CNC side
Machine side
0V