Chapter 3 - Setup Instructions
3-47
3-5-7-1
Connection directly to the Voluson i / Voluson e system
(cont’d)
NOTE:
The power switch on the rear of the DVD drive (Addonics only) must be set in the
External
position, as
shown below:
The DVD+R/RW Drive can be connected once the system is powered ON, or after shutdown.
NOTE:
When connecting the DVD+R/RW Drive to the Voluson i / Voluson e system, it might be possible that
the Drive is not recognized in the “Connect USB and Network Drives” dialog window.
To check connection, perform:
Section 3-5-7-5-1 "After physical connection" on page 3-48
.
3-5-7-2
Connection via USB hub
As stated above.
Safety considerations must be taken into account.
The USB hub and the DVD+R/RW Drive must be powered via an isolation transformer.
An USB port may be used to communicate with the DVD device.
3-5-7-3
Voluson i / Voluson e mounted on Modo Cart
The DVD+R/RW Drive may be connected to the USB ports on the rear of the Voluson i / Voluson e.
A power cable that extends from the power outlets of the Modo Carts isolation transformer should be
used to connect the power supply of the DVD+R/RW drive.
The DVD+R/RW can be placed in the upper peripheral storage shelf on the Modo Cart (refer to
Figure
3-10 on page 3-14
). The power cable (described above) is then plugged into the rear of the DVD device
and the data cable is connected to the USB port.
3-5-7-4
Voluson i / Voluson e mounted on Dock Cart
The DVD+R/RW Drive may be connected to the USB ports on the rear of the Voluson i / Voluson e.
A power cable that extends from the power outlets of the Dock Carts power supply should be used to
connect the power supply of the DVD+R/RW drive.
The DVD+R/RW should be placed in the Tray Recorder on the Dock Cart (refer to
Figure 3-12 on page
3-16
). The power cable (described above) is then plugged into the rear of the DVD device and the data
cable is connected to the USB port.
3-5-7-5
Voluson i / Voluson e mounted on Voluson Station
The DVD+R/RW Drive is premounted on the Voluson Station.
CAUTION
!! CAUTION:
When connecting directly to the system, it is necessary to use additional power supply (supplied with
the drive).
As a safety requirement, this must be done via an isolation transformer.
NOTICE
!! NOTICE:
IMPORTANT
During software installation, the DVD drive
must be connected directly
to the
Voluson i / Voluson e portable ultrasound system.
External
Power OFF
Internal
Содержание Voluson i BT06
Страница 2: ......
Страница 11: ...GE VOLUSON i VOLUSON e DIRECTION KTI106052 REVISION 10 SERVICE MANUAL ix ZH CN KO...
Страница 44: ...GE VOLUSON i VOLUSON e DIRECTION KTI106052 REVISION 10 SERVICE MANUAL xlii Table of Contents...
Страница 514: ...GE VOLUSON i VOLUSON e DIRECTION KTI106052 REVISION 10 SERVICE MANUAL IV Index...
Страница 515: ......