6-26
T60 Transformer Protection System
GE Multilin
6.3 METERING
6 ACTUAL VALUES
6
6.3.12 RESTRICTED GROUND FAULT
PATH: ACTUAL VALUES
METERING
RESTRICTED GROUND FAULT CURRENTS
RESTRICTED GROUND FAULT 1(6)
The differential and restraint current values for the restricted ground fault element are displayed in this menu.
6.3.13 TRANSDUCER INPUTS AND OUTPUTS
PATH: ACTUAL VALUES
METERING
TRANSDUCER I/O DCMA INPUTS
DCMA INPUT xx
Actual values for each dcmA input channel that is enabled are displayed with the top line as the programmed channel ID
and the bottom line as the value followed by the programmed units.
PATH: ACTUAL VALUES
METERING
TRANSDUCER I/O RTD INPUTS
RTD INPUT xx
Actual values for each RTD input channel that is enabled are displayed with the top line as the programmed channel ID and
the bottom line as the value.
6.3.14 DISTANCE
PATH: ACTUAL VALUES
METERING
DISTANCE
RESTRICTED
GROUND FAULT 1
RGF 1 DIFF
Igd:
0.000
A
MESSAGE
RGF 1 RESTR Igr:
0.000
A
DCMA INPUT xx
DCMA INPUT xx
0.000 mA
RTD INPUT xx
RTD INPUT xx
-50 °C
DISTANCE
AB LOOP RESISTANCE
RAB: 0.00 Ohms
MESSAGE
AB LOOP REACTANCE
XAB: 0.00 Ohms
MESSAGE
AB LOOP IMPEDANCE
ZAB: 0.00 Ohms
MESSAGE
AB LOOP IMPEDANCE
ANGLE: 0.00 DEG
MESSAGE
BC LOOP RESISTANCE
RBC: 0.00 Ohms
MESSAGE
BC LOOP REACTANCE
XBC: 0.00 Ohms
MESSAGE
BC LOOP IMPEDANCE
ZBC: 0.00 Ohms
MESSAGE
BC LOOP IMPEDANCE
ANGLE: 0.00 DEG
MESSAGE
CA LOOP RESISTANCE
RCA: 0.00 Ohms
MESSAGE
CA LOOP REACTANCE
XCA: 0.00 Ohms
Содержание T60
Страница 6: ...vi T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Страница 14: ...xiv T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Страница 34: ...1 20 T60 Transformer Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 118: ...3 48 T60 Transformer Protection System GE Multilin 3 3 DIRECT INPUT OUTPUT COMMUNICATIONS 3 HARDWARE 3 ...
Страница 146: ...4 28 T60 Transformer Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 490: ...5 344 T60 Transformer Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 522: ...6 32 T60 Transformer Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 536: ...7 14 T60 Transformer Protection System GE Multilin 7 1 COMMANDS 7 COMMANDS AND TARGETS 7 ...
Страница 538: ...8 2 T60 Transformer Protection System GE Multilin 8 1 DIRECTIONAL PRINCIPLE 8 THEORY OF OPERATION 8 ...
Страница 568: ...10 12 T60 Transformer Protection System GE Multilin 10 6 DISPOSAL 10 MAINTENANCE 10 ...
Страница 596: ...A 28 T60 Transformer Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 716: ...B 120 T60 Transformer Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Страница 762: ...E 10 T60 Transformer Protection System GE Multilin E 1 IEC 60870 5 104 PROTOCOL APPENDIX E E ...
Страница 774: ...F 12 T60 Transformer Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Страница 785: ...GE Multilin T60 Transformer Protection System H 9 APPENDIX H H 2 ABBREVIATIONS H Z Impedance Zone ...