GE Multilin
T60 Transformer Protection System
A-15
APPENDIX A
A.1 PARAMETER LISTS
A
10312
SRC 1 Ic Harm[7]
%
Source 1 phase C current seventh harmonic
10313
SRC 1 Ic Harm[8]
%
Source 1 phase C current eighth harmonic
10314
SRC 1 Ic Harm[9]
%
Source 1 phase C current ninth harmonic
10315
SRC 1 Ic Harm[10]
%
Source 1 phase C current tenth harmonic
10316
SRC 1 Ic Harm[11]
%
Source 1 phase C current eleventh harmonic
10317
SRC 1 Ic Harm[12]
%
Source 1 phase C current twelfth harmonic
10318
SRC 1 Ic Harm[13]
%
Source 1 phase C current thirteenth harmonic
10319
SRC 1 Ic Harm[14]
%
Source 1 phase C current fourteenth harmonic
10320
SRC 1 Ic Harm[15]
%
Source 1 phase C current fifteenth harmonic
10321
SRC 1 Ic Harm[16]
%
Source 1 phase C current sixteenth harmonic
10322
SRC 1 Ic Harm[17]
%
Source 1 phase C current seventeenth harmonic
10323
SRC 1 Ic Harm[18]
%
Source 1 phase C current eighteenth harmonic
10324
SRC 1 Ic Harm[19]
%
Source 1 phase C current nineteenth harmonic
10325
SRC 1 Ic Harm[20]
%
Source 1 phase C current twentieth harmonic
10326
SRC 1 Ic Harm[21]
%
Source 1 phase C current twenty-first harmonic
10327
SRC 1 Ic Harm[22]
%
Source 1 phase C current twenty-second harmonic
10328
SRC 1 Ic Harm[23]
%
Source 1 phase C current twenty-third harmonic
10329
SRC 1 Ic Harm[24]
%
Source 1 phase C current twenty-fourth harmonic
10330
SRC 1 Ic Harm[25]
%
Source 1 phase C current twenty-fifth harmonic
10339
SRC 2 Ia THD
%
Source 2 phase A current total harmonic distortion
10340
SRC 2 Ia Harm[2]
%
Source 2 phase A current second harmonic
10341
SRC 2 Ia Harm[3]
%
Source 2 phase A current third harmonic
10342
SRC 2 Ia Harm[4]
%
Source 2 phase A current fourth harmonic
10343
SRC 2 Ia Harm[5]
%
Source 2 phase A current fifth harmonic
10344
SRC 2 Ia Harm[6]
%
Source 2 phase A current sixth harmonic
10345
SRC 2 Ia Harm[7]
%
Source 2 phase A current seventh harmonic
10346
SRC 2 Ia Harm[8]
%
Source 2 phase A current eighth harmonic
10347
SRC 2 Ia Harm[9]
%
Source 2 phase A current ninth harmonic
10348
SRC 2 Ia Harm[10]
%
Source 2 phase A current tenth harmonic
10349
SRC 2 Ia Harm[11]
%
Source 2 phase A current eleventh harmonic
10350
SRC 2 Ia Harm[12]
%
Source 2 phase A current twelfth harmonic
10351
SRC 2 Ia Harm[13]
%
Source 2 phase A current thirteenth harmonic
10352
SRC 2 Ia Harm[14]
%
Source 2 phase A current fourteenth harmonic
10353
SRC 2 Ia Harm[15]
%
Source 2 phase A current fifteenth harmonic
10354
SRC 2 Ia Harm[16]
%
Source 2 phase A current sixteenth harmonic
10355
SRC 2 Ia Harm[17]
%
Source 2 phase A current seventeenth harmonic
10356
SRC 2 Ia Harm[18]
%
Source 2 phase A current eighteenth harmonic
10357
SRC 2 Ia Harm[19]
%
Source 2 phase A current nineteenth harmonic
10358
SRC 2 Ia Harm[20]
%
Source 2 phase A current twentieth harmonic
10359
SRC 2 Ia Harm[21]
%
Source 2 phase A current twenty-first harmonic
10360
SRC 2 Ia Harm[22]
%
Source 2 phase A current twenty-second harmonic
10361
SRC 2 Ia Harm[23]
%
Source 2 phase A current twenty-third harmonic
10362
SRC 2 Ia Harm[24]
%
Source 2 phase A current twenty-fourth harmonic
10363
SRC 2 Ia Harm[25]
%
Source 2 phase A current twenty-fifth harmonic
10372
SRC 2 Ib THD
%
Source 2 phase B current total harmonic distortion
10373
SRC 2 Ib Harm[2]
%
Source 2 phase B current second harmonic
10374
SRC 2 Ib Harm[3]
%
Source 2 phase B current third harmonic
Table A–1: FLEXANALOG DATA ITEMS (Sheet 15 of 26)
ADDRESS
FLEXANALOG NAME
UNITS
DESCRIPTION
Содержание T60
Страница 6: ...vi T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Страница 14: ...xiv T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Страница 34: ...1 20 T60 Transformer Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 118: ...3 48 T60 Transformer Protection System GE Multilin 3 3 DIRECT INPUT OUTPUT COMMUNICATIONS 3 HARDWARE 3 ...
Страница 146: ...4 28 T60 Transformer Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 490: ...5 344 T60 Transformer Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 522: ...6 32 T60 Transformer Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 536: ...7 14 T60 Transformer Protection System GE Multilin 7 1 COMMANDS 7 COMMANDS AND TARGETS 7 ...
Страница 538: ...8 2 T60 Transformer Protection System GE Multilin 8 1 DIRECTIONAL PRINCIPLE 8 THEORY OF OPERATION 8 ...
Страница 568: ...10 12 T60 Transformer Protection System GE Multilin 10 6 DISPOSAL 10 MAINTENANCE 10 ...
Страница 596: ...A 28 T60 Transformer Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 716: ...B 120 T60 Transformer Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Страница 762: ...E 10 T60 Transformer Protection System GE Multilin E 1 IEC 60870 5 104 PROTOCOL APPENDIX E E ...
Страница 774: ...F 12 T60 Transformer Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Страница 785: ...GE Multilin T60 Transformer Protection System H 9 APPENDIX H H 2 ABBREVIATIONS H Z Impedance Zone ...