GE Multilin
T60 Transformer Protection System
B-95
APPENDIX B
B.4 MEMORY MAPPING
B
F237
ENUMERATION: REAL TIME CLOCK MONTH (FOR EXAMPLE,
DAYLIGHT SAVINGS TIME)
F238
ENUMERATION: REAL TIME CLOCK DAY (FOR EXAMPLE,
DAYLIGHT SAVINGS TIME)
F239
ENUMERATION: REAL TIME CLOCK DAYLIGHT SAVINGS
TIME START DAY INSTANCE
134
GGIO3.MX.AnIn6.mag.f
135
GGIO3.MX.AnIn7.mag.f
136
GGIO3.MX.AnIn8.mag.f
137
GGIO3.MX.AnIn9.mag.f
138
GGIO3.MX.AnIn10.mag.f
139
GGIO3.MX.AnIn11.mag.f
140
GGIO3.MX.AnIn12.mag.f
141
GGIO3.MX.AnIn13.mag.f
142
GGIO3.MX.AnIn14.mag.f
143
GGIO3.MX.AnIn15.mag.f
144
GGIO3.MX.AnIn16.mag.f
145
GGIO3.MX.AnIn17.mag.f
146
GGIO3.MX.AnIn18.mag.f
147
GGIO3.MX.AnIn19.mag.f
148
GGIO3.MX.AnIn20.mag.f
149
GGIO3.MX.AnIn21.mag.f
150 GGIO3.MX.AnIn22.mag.f
151 GGIO3.MX.AnIn23.mag.f
152 GGIO3.MX.AnIn24.mag.f
153 GGIO3.MX.AnIn25.mag.f
154 GGIO3.MX.AnIn26.mag.f
155 GGIO3.MX.AnIn27.mag.f
156 GGIO3.MX.AnIn28.mag.f
157 GGIO3.MX.AnIn29.mag.f
158 GGIO3.MX.AnIn30.mag.f
159 GGIO3.MX.AnIn31.mag.f
160 GGIO3.MX.AnIn32.mag.f
161 GGIO3.ST.IndPos1.stVal
162 GGIO3.ST.IndPos2.stVal
163 GGIO3.ST.IndPos3.stVal
164 GGIO3.ST.IndPos4.stVal
165 GGIO3.ST.IndPos5.stVal
166 GGIO3.ST.UIntIn1.q
167 GGIO3.ST.UIntIn1.stVal
168 GGIO3.ST.UIntIn2.q
169 GGIO3.ST.UIntIn2.stVal
170 GGIO3.ST.UIntIn3.q
171 GGIO3.ST.UIntIn3.stVal
172 GGIO3.ST.UIntIn4.q
173 GGIO3.ST.UIntIn4.stVal
174 GGIO3.ST.UIntIn5.q
175 GGIO3.ST.UIntIn5.stVal
176 GGIO3.ST.UIntIn6.q
177 GGIO3.ST.UIntIn6.stVal
178 GGIO3.ST.UIntIn7.q
179 GGIO3.ST.UIntIn7.stVal
180 GGIO3.ST.UIntIn8.q
181 GGIO3.ST.UIntIn8.stVal
182 GGIO3.ST.UIntIn9.q
183 GGIO3.ST.UIntIn9.stVal
184 GGIO3.ST.UIntIn10.q
185 GGIO3.ST.UIntIn10.stVal
Value
IEC 61850 GOOSE Rx dataset
item
186 GGIO3.ST.UIntIn11.q
187 GGIO3.ST.UIntIn11.stVal
188 GGIO3.ST.UIntIn12.q
189 GGIO3.ST.UIntIn12.stVal
190 GGIO3.ST.UIntIn13.q
191 GGIO3.ST.UIntIn13.stVal
192 GGIO3.ST.UIntIn14.q
193 GGIO3.ST.UIntIn14.stVal
194 GGIO3.ST.UIntIn15.q
195 GGIO3.ST.UIntIn15.stVal
196 GGIO3.ST.UIntIn16.q
197 GGIO3.ST.UIntIn16.stVal
Value
Month
0
January
1
February
2
March
3
April
4
May
5
June
6
July
7
August
8
September
9
October
10
November
11
December
Value
Day
0
Sunday
1
Monday
2
Tuesday
3
Wednesday
4
Thursday
5
Friday
6
Saturday
Value
Instance
0
First
1
Second
2
Third
Value
IEC 61850 GOOSE Rx dataset
item
Содержание T60
Страница 6: ...vi T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Страница 14: ...xiv T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Страница 34: ...1 20 T60 Transformer Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 118: ...3 48 T60 Transformer Protection System GE Multilin 3 3 DIRECT INPUT OUTPUT COMMUNICATIONS 3 HARDWARE 3 ...
Страница 146: ...4 28 T60 Transformer Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 490: ...5 344 T60 Transformer Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 522: ...6 32 T60 Transformer Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 536: ...7 14 T60 Transformer Protection System GE Multilin 7 1 COMMANDS 7 COMMANDS AND TARGETS 7 ...
Страница 538: ...8 2 T60 Transformer Protection System GE Multilin 8 1 DIRECTIONAL PRINCIPLE 8 THEORY OF OPERATION 8 ...
Страница 568: ...10 12 T60 Transformer Protection System GE Multilin 10 6 DISPOSAL 10 MAINTENANCE 10 ...
Страница 596: ...A 28 T60 Transformer Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 716: ...B 120 T60 Transformer Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Страница 762: ...E 10 T60 Transformer Protection System GE Multilin E 1 IEC 60870 5 104 PROTOCOL APPENDIX E E ...
Страница 774: ...F 12 T60 Transformer Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Страница 785: ...GE Multilin T60 Transformer Protection System H 9 APPENDIX H H 2 ABBREVIATIONS H Z Impedance Zone ...