SVmco User Guidel
820
28502
SV RAID:%2 Adapter error (BBU temperature above threshold) vendor-
id=1000/1734 device-id=%d revision=%r
Meaning:
A temperature detected by the temperature sensor on the battery exceeded the
upper threshold.
%2: Device name
%d: (Example) 0060/10F9 (device-id/sub device-id)
%r: Numerical value (1 to 3 digits)
Corrective action:
Check the fan status in ServerView. If a fan failure occurred, take corrective
action for the target unit.
If no fan failure occurred, recheck the environment temperature. If the error
recurs after you rechecked the environment temperature, replace the BBU.
Severity:
Error
Action:
(R/M/T/S)
28503
SV RAID:%2 Adapter error (BBU voltage out of range) vendor-id=1000/1734
device-id=%d revision=%r
Содержание PRIMEQUEST 1000 Series
Страница 8: ......
Страница 180: ...SVmco User Guidel 172 Teaming tab ...
Страница 203: ...SVmco User Guide 195 5 Click the Sessions tab in the Properties window and click the MCS button Properties window ...
Страница 219: ...SVmco User Guide 211 1 Confirm that the PSA MMB_LAN chain has been created sbin iptables L ...