SVmco User Guidel
840
Many defective blocks cannot be recovered. If a file cannot be read, restore the
file from a backup.
Severity:
Error
Action:
(R/M/T/S)
28532
SV RAID:%2 Adapter error (BBU/charger problems detected; SOH bad)
vendor-id=1000/1734 device-id=%d revision=%r
Meaning:
A BBU charger problem was detected.
%2: Device name
%d: (Example) 0060/10F9 (device-id/sub device-id)
%r: Numerical value (1 to 3 digits)
Corrective action:
Replace the BBU. If the error recurs, replace the possibly faulty component of
the SAS interface system.
Severity:
Warning
Action:
(R/M/T/S)