SVmco User Guide
865
Action:
(R/M/T/S)
28571
SV RAID:%2 Device error (Microcode update failed on disk)
Meaning:
The HDD firmware update failed.
%2: Device name
Corrective action:
If the HDD is faulty, replace the HDD, and perform a rebuild.
Severity:
Warning
Action:
(R/M/T/S)
28572
SV RAID:%2 Device error (Adapter cache pinned for missing or offline
logical drive)
Meaning:
For the missing logical drive, the cached data of the SAS array controller card
has been saved.
%2: Device name