SVmco User Guidel
142
From the above example, you can confirm that the Fault LED of slot 2 of
ioc0 is on, so sdc was surveyed in that slot.
2) Turn off the Fault LED by executing the following disk management
command.
# /opt/fujitsu/SVmco/bin/diskctrl -o ioc0/2
The Fault LED goes out.
Display the status by executing the disk management command.
You can confirm that "none" is displayed as the device name of slot 2 of
ioc0 and the slot is empty.
# /opt/fujitsu/SVmco/bin/diskctrl -l
ioc0
0 /dev/sda
Fault LED-Off
1 /dev/sdb
Fault LED-Off
2 none
3 /dev/sdd
Fault LED-Off
4.2.3.
Replacement procedure (for hard disk
failures not causing non-responsiveness)