%d: (Example) 0060/10F9 (device-id/sub device-id)
%r: Numerical value (1 to 3 digits)
Corrective action:
Replace the BBU. If the error recurs, replace the possibly faulty component of
the SAS interface system.
Severity:
Error
Action:
(R/M/T/S)
28516
SV RAID:%2 Adapter error (BBU temperature problem detected) vendor-
id=1000/1734 device-id=%d revision=%r
Meaning:
An abnormal battery temperature was detected.
%2: Device name
%d: (Example) 0060/10F9 (device-id/sub device-id)
%r: Numerical value (1 to 3 digits)
Corrective action:
Check the fan status in ServerView. If a fan failure occurred, take corrective
action for the target unit. If no fan failure occurred, recheck the environment
temperature. If the error recurs after you rechecked the environment
temperature, replace the BBU.