SVmco User Guide
723
18556
SV RAID:%2 Device error (State change on disk from operational to failed)
Meaning:
The HDD state changed from operational to failed.
%2: Device name
Corrective action:
Replace the failed HDD. Perform a rebuild.
Severity:
Error
Action:
(R/M/T/S)
18557
SV RAID:%2 Device error (Disk missing after reboot)
Meaning:
The HDD could not be found at restart.
%2: Device name
Corrective action:
Replace the HDD. Perform a rebuild. If the Fault LED is not on, a SAS interface
system failure may have occurred. Replace the possibly faulty component of the
SAS interface system. However, this event may occur on starting the operating